AQUASPEC FAUCETS

MODEL - Z86500 SERIES

CENTERSET METERING

TECHNICAL INFORMATION

FLOW:

  0.25 GPC MAXIMUM; PRESET AT FACTORY TO 10 SECOND @ 80 PSI ADJUSTABLE

MAXIMUM PRESSURE:

  125 PSI

MAXIMUM TEMPERATURE:

  180

O

 

F

F

®

INSTALLATION INSTRUCTIONS

1.

THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.

2.

REMOVE FAUCET BODY FROM CARTON AND PLACE FAUCET ON SINK.

3.

ATTACH MOUNTING NUTS (#7A) ONTO SHANKS FROM UNDER SINK.

4.

HAND TIGHTEN MOUNTING NUTS (#7A).  DO NOT OVER TIGHTEN, YOU COULD DAMAGE THE FIXTURE.

5.

ATTACH LAVATORY SUPPLY TO THE OUTLET OF THE SUPPLY STOP AND CONNECT TO FAUCET WITH RISER NUT
(#7B).

6.

OPTIONAL - POP-UP (-P)/ GRID STRAINER (-G)/HANDICAP OFFSET GRID DRAIN (-GH):
INSTALL POP-UP OR GRID STRAINER IN SINK OUTLET AND PLUMB WASTE CONNECTION.

7.

TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS

8.

INSTALL  SPRAY OUTLET (#6) INTO FAUCET AND HAND TIGHTEN.

9.

METERING CARTRIDGE IS FACTORY PRESET FOR A 10 SECOND CYCLE AT 80 PSI, IF ADJUSTMENT IS
NECESSARY, SEE “ADJUSTING THE FLOW” SECTION (PAGE 2).

PAGE 1 OF 4

*

Form #

 CF102

Date:

 4/2/07

C.N. No.

 106044

Rev.

 M

IMPORTANT

THE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT

FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS AND THEREBY PREVENTING
THE FAUCET FROM FUNCTIONING PROPERLY

IMPORTANT

THE FAUCET HAS AN INTEGRAL SHANK FILTER ASSEMBLY INSTALLED IN THE BODY UNDER THE METERING

CARTRIDGE TO PREVENT FOREIGN MATTER AND DEBRIS FROM DAMAGING THE FAUCET. THE INTEGRAL FILTER MAY BE
REMOVED TO BE BACK-FLUSHED AND CLEANED IF INSUFFICIENT FLOW IS DETECTED. THE INTEGRAL SHANK FILTER
ASSEMBLY MUST BE RE-INSTALLED AFTER SERVICING TO ENSURE PROPER FUNCTIONING OF THE METERING CARTRIDGE.

- CAN USE QUARTER TURN CERAMIC DISK CARTRIDGE

Summary of Contents for AQUASPEC Z86500 Series

Page 1: ... 7 TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS 8 INSTALL SPRAY OUTLET 6 INTO FAUCETAND HAND TIGHTEN 9 METERING CARTRIDGE IS FACTORY PRESET FOR A 10 SECOND CYCLE AT 80 PSI IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE FLOW SECTION PAGE 2 PAGE 1 OF 4 Form CF102 Date 4 2 07 C N No 106044 Rev M IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PR...

Page 2: ... 8 HEX 6 POINT SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING HOLD DOWN HANDLES 1A 1B WHILE TIGHTENING SET SCREW 1C TO ENSURE PROPER SEATING 3 IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THE INTEGRAL SHANK FILTER AND AERATOR PERIODICALLY TO REMOVE COLLECTED SEDIMENT AND DEBRIS 3 1 INTEGRAL SHANK FILTER 4 IS REMOVED USING A 1 4 ALLEN WRENCH REPLACEME...

Page 3: ...3 Stem 1 2C 60450001 Spring Seat 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 Item Part Number Description Qty 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2I 60458001 O Ring Retainer 1 3 G61754 Metering Cartridge Ass y 2 3A 81121001 O Ring 1 3B 81241001 Washer 1 4 G67787 Integral Shank Filter 2 5 92109001 4 102mm Centerset Body 1 6 G63561 13 16 27 Male Spray Outlet 0 2...

Page 4: ...s adjustment Aerator is not installed or incorrect aerator installed Metering cartridge is overly contaminated or damaged Faucet will not shut off Faucet is making noise at shutoff Handles becoming loose with normal usage Install 1 0 GPM or 0 5 GPM aerator Facuet may not shut off with aerator s 1 0 GPM Tighten handle nut using 1 1 8 hex 6 point socket to create seal and seat metering cartridge Do ...

Reviews: