background image

MAINTENANCE

1. YOUR ZURN AQUASPEC FAUCET HAS A HIGHLY POLISHED NICKEL CHROME PLATED FINISH.  CLEAN WITH SOAP  AND

WATER OR A MILD CLEANER WHICH IS SAFE FOR CHROME PLATING.  DO NOT USE ACIDS OR TOILET BOWL CLEANER
AS THEY WILL DAMAGE THE FINISH.

2. AQUASPEC FAUCETS CONTAIN CERAMIC DISK CARTRIDGES WHICH REQUIRE NO MAINTENANCE.  TO REMOVE THE

CARTRIDGE SHUT THE WATER OFF, LOOSEN THE HANDLE NUTS AND PULL OUT ON THE CARTRIDGE.

INSTALLATION INSTRUCTIONS

1. REMOVE FAUCET BODY FROM CARTON AND INSTALL FRICTION GASKET (ITEM #5A) ON SHANK.

2.

OPTIONAL ANTI-ROTATION PIN (-AR), THREAD ANTI-ROTATION PIN INTO THE THREADED HOLE ON THE UNDER
SIDE OF THE DOUBLE LAB BODY.  SEE PAGE 2 FOR ROUGH-IN DIMENSIONS TO ACCOMODATE THE (-AR) OPTION.

3. PLACE FAUCET ON SINK AND SECURE WITH WASHER (ITEM #5B)  AND MOUNTING NUT (ITEM #5C).

4. TIGHTEN MOUNTING NUT FROM UNDER SINK.  MAKE SURE FAUCET IS CENTERED PROPERLY.  DO NOT OVER

TIGHTEN.

5. INSTALL SPOUT INTO BASE AND TIGHTEN NUT (SEE VIEWS FOR SWING/RIGID CONNECTION).

6.  ATTACH FLEX HOSE LAVATORY SUPPLIES (ITEM #6) TO FAUCET.

7. OPTIONAL GRID STRAINER (-G) / HANDICAP OFFSET GRID DRAIN (-GH)

INSTALL GRID STRAINER IN SINK OUTLET AND PLUMB WASTE CONNECTION.

8.  TURN  WATER SUPPLY ON AND OPERATE FAUCET CHECKING FOR LEAKS.

9.  IT MAY BE NECESSARY TO SHUT WATER OFF AND REMOVE CARTRIDGES TO CLEAN SUPPLY LINES.  CARTRIDGES

CAN BE REMOVED BY FIRST REMOVING THE HANDLES.  COLOR INDEXES CAN BE REMOVED BY INSERTING A PIN
INTO THE HOLE ON THE UNDERSIDE OF THE HANDLE.   AFTER THE HANDLES HAVE BEEN REMOVED UNSCREW THE
HANDLE NUTS  AND PULL OUT ON THE CARTRIDGE.  ZURN WILL SUPPLY HANDLE PORT
PLUGS (ZURN PART #61094001)  AT YOUR REQUEST.

10. REPLACE CARTRIDGES IN BODY AND HAND TIGHTEN HANDLE NUTS.  PLACE HANDLES ON THE CARTRIDGE STEM

 AND LOCATE THEM AS DESIRED.  TIGHTEN HANDLE NUT.

11. REPLACE HANDLE SCREWS  AND COLOR INDEX BUTTONS.

12. INSTALL AERATOR INTO FAUCET AND HAND TIGHTEN.  IT MAY BE NECESSARY TO UNSCREW AND CLEAN AERATOR AT

START-UP.

SHT 1 OF 2

AQUASPEC FAUCETS

MODEL - Z82600 SERIES

SINGLE HOLE, DOUBLE LABORATORY FAUCET

TECHNICAL INFORMATION

FLOW:  2.2 GPM [8.3L] PRESSURE COMPENSATING AERATOR *
MAXIMUM PRESSURE:  125 PSI
MAXIMUM TEMPERATURE:  180

F

F

HANDLE NUT TORQUE:  15-20 FT - LBS.
CARTRIDGE STYLE:  QUARTER TURN CERAMIC DISK

* OTHER AERATORS AVAILABLE BY REQUEST

Form #

 CF100

Date:

 1/29/07

C.N. No.

 105622

Rev.

 H

Reviews: