background image

 

  011319-03

                                                                                                                                                  

12

 

 

 

Technical instructions 

 

Z22 

 

 

In case there will be a contact damaged we will proceed to change it with a flat screwdriver 
pressing down the plastic lever (yellow arrow) and the contact will drop down.  After turning 
half a round, the small torx socket screw (yellow circle) the button could be separated from the 
contact  box.  If  we  have  to  change the  button,  we  must  pay  attention  that  the  arrow  on  the 
contact  box  must  be  in  the  same  position  as  in  the  picture  below.

 

When  the  button  is 

assembled again, then we turn half a round the torx socket screw and we have finished. 

 

 

 

 

 

 

d) 

After  doing  the  buttons  verification  we  will  proceed  to  check  if  the  micro-switch  is  working 
properly. We will use the voltmeter and verify that there is no continuity at the open contact of 
the  switch  (yellow  marks)  and  when  we  trigger  the  switch  (green  mark)  we  should  have 
continuity. If it happens it means that the switch is ok. 

 

 

 

 

 

 

 

 

 

Summary of Contents for Z22

Page 1: ...disc change 5 Electric diagram 6 Troubleshooting 1 Disassemble machine 1 1 This juicer machine has a metallic locking arm that allows locking the machine up while working When the locking arm is unlocked turns a micro switch off and it makes that the juicer doesn t works and we can work safety Otherwise we should disconnect the mains before doing anything with the machine ...

Page 2: ...e have the locking arm unlocked we proceed to remove the juicer cover and pull the bowl out and all the pieces from the basket Be careful for not to cut you off with the grating disc We should remove all the pieces as shown on the picture below Fig 1 ...

Page 3: ...ill find the other two screws then remove them too Very important before removing the plastic base don t forget to make a reference mark that show us which is the correct position 2 2 Once the base is removed we have to unscrew four screws of the fixed guideway and remove also four springs that fasten this fixed guideway to the mobile guideway just under the fixed one that one has the micro switch...

Page 4: ... connectors at the same time with an insulated screwdriver Next step is to remove the locking arm first we unscrew two hexagon socket screws on both sides and then by stretching both sides of the locking arm out Upon removal of the locking arm we could be able to pull the mobile guideway out by unscrewing the bolt and the rubber washer that fix it to the motor ...

Page 5: ...that there is nothing that disturb at the rear of the motor so that we would have free access to handle the motor it s highly important to take care that all the wires below don t disturb us before trying to dismantle the motor 2 5 Right after we turn around the machine and we have to pull the drive disc out by unscrewing the hexagonal socket set screw that fix it to the motor shaft ...

Page 6: ...remove it faster it s better that you do it slowly 2 7 Once the rubber cover is out we will see 4 Allen bolts that fix the motor to the motor housing Be extremely careful because when loosening the 4 bolts the motor remains free and it can fall down When we have the bolts removed we can proceed to pull the motor out from the other side bearing in mind that we have cables on the other side that can...

Page 7: ...he housing and then tightening the 4 Allen screws again Next step will be fitting again the rubber cover Pay attention that the cover fits on the machine first on the slot and after on all the sides and the with the help of a flat screwdriver fit the center of the cover in the hole of the joints ...

Page 8: ... in the same position as in the picture 3 2 Once we have both guideways assembled the fixed one has 4 screws on the corners and the mobile one has a rubber washer and a hexagonal bolt we proceed to assemble the plastic base and screw it to the machine Warning Be careful before screwing this base it only has one possible position and you can only screw it properly when you find it The plastic piece...

Page 9: ...be connected ALWAYS at the hexagon socket screw of the locking arm fitting and to the chassis also with a screw see green marks 4 Grating disc change 4 1 For changing the grating disc we must disconnect the mains and then proceed to remove all the stuff of the bowl as shown on the picture below Fig 2 ...

Page 10: ...011319 03 10 Technical instructions Z22 5 Electric diagram ...

Page 11: ... still not working we must try to move the grating disc carefully to check if it can be move easily with the hand It s for ensure that the motor is not blocked Proceed always with the machine disconnected from the mains c If the grating disc moves softly and it s not blocked we will proceed to dismantle the plastic base cover for leaving visible the buttons see point 2 1 Once we have both buttons ...

Page 12: ...the button we must pay attention that the arrow on the contact box must be in the same position as in the picture below When the button is assembled again then we turn half a round the torx socket screw and we have finished d After doing the buttons verification we will proceed to check if the micro switch is working properly We will use the voltmeter and verify that there is no continuity at the ...

Page 13: ...at all the steps we did before are correct and we didn t find any failure we must check the motor s resistance For check the resistance we will use the voltmeter in the resistance measure position symbol Ω If the motor is ok the measure should be around 1 2Ω and if there s no value at the measure the motor should be changed g In case of all the previous verifications have been ok and the motor res...