Zublin Pro LED 200 Quick Start Manual Download Page 1

 

Warning!  

- Any work on the mains power supply must only be completed by trained specialists. 
- The product must be installed in accordance with country-specific  
  installation guidelines/standards. 
- Disconnect the 230-volt power supply before 
  starting the installation process! 
- As a precautionary measure, the power supply of the light should always be fitted with a (250VAC, 10A)  
  type C fuse in accordance with EN60898-1. 
- The device must be fitted with an earthed conductor (earth).  
- Only change the light bulb/touch the housing once  
  the light has cooled down. 

 

- Only operate the device with the specific lamps intended for that purpose. 
- Faulty lamps can cause a short-circuit  
  thereby permanently damaging the device. 
- Any faulty devices should be disconnected from the power supply. 
-

 

The light is not suitable for installation on easily flammable  

  surfaces. 
- Installation in internal spaces is permitted as long as there is no risk of  
  overheating.  
- Any broken protection glass must be replaced immediately. 

Care and maintenance  

Before any cleaning and maintenance work is completed on the light,  
it must first be left to cool and the fuse for the relevant  
power supply must be switched off.  
For electrical safety purposes, the light must not be cleaned with water  
or any other liquids and must not be submerged in water.  
Therefore, only use a dry, lint-free cloth when cleaning. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase/outer conductor (L): brown; 
Neutral/neutral conductor (N): blue; 
Earth: green/yellow 
 
Switching output/switched phase/outer 
conductor (L') red and white; for parallel 
bypass (continuous light) or for additional 
loads. We recommend switching a maximum 
of two flood lights in parallel. If the switching 
capacity is higher, the additional load can be 
switched via an external relay. 
 

Sensor light Pro 19W/35W LED, 120W/400W  Page 1/2 

 

Turn the head of the light (1) by 180° into the 
service position. Loosen the screw (2) at the 
bottom of the device so that the cover (3) can be 
pushed down. Then engage the lug on the 
device with the middle screw (4) and attach the 
device with the two remaining screws (5). Once 
the installation is complete, turn the head back 
into the operational position. 
 

To ensure the operational reliability, install the 
device in an area that is protected from the 
elements. Maintain a safety distance of 20 cm 
to ceilings (30 cm if installed in an internal 
corner) and 1 m to illuminated objects. Avoid 
heat sources in the immediate coverage area 
as well as under the detector. 

Installati
on 
 

Power supply 

Alignment 
 

Settings 

Installation 
site 

 

 

 

 

Specifications: 

Nominal voltage: 220 to 240V, 50Hz 
Light output: in accordance with the type of 
lamp 
Coverage area: 200°/140° according to the 
model 
Range: 12 m ahead 
Twilight controller: 5 to 1000 lux 
Time controller: 3 seconds to 30 minutes 
Protection class: IP55, class I 
Ambient temperature: -20°C to +40°C 

Pro 19W LED 200 
8 x high-power 
LEDs 

Pro 35W LED 200 
15 x high-power 
LEDs 

Pro 120W 200 
Pro 120W 140 

Use a clean cloth to touch the 
halogen bulb. Otherwise finger 
prints and grease residues will 
burn in and reduce the service life 
of the lamp. 

Approx. 5 lux (night) to 
 1000 lux (day) 

Follow-up time 
approx. 3 seconds to 
30 minutes 

 

            Frontal detection  
            

NOT SENSITIVE 

            Distance approx. -50% 
 
Tangential detection  
 = 

SENSITIVE

 

 

The range is dependent on the installation location and the 
direction of movement. As the motion detector reacts to the 
temperature fluctuations between the heat source and ambient 
temperature, the range can vary depending on the installation 
location.

 

Coverage area 
 

Pro 400W 200 
Pro 400W 140 

The head of the light can now be adjusted 
horizontally and vertically by approx. +/-10°. Ensure 
that the halogen bulb only deviates from the 
horizontal axis by a max. of 4° otherwise this will 
cause a one-sided accumulation of heat. The device 
cannot be operated while in the service position. 