ZXSDR RSUC User Manual
Figure 5-10 Installing the RSU Monitoring Cable
– End of Steps –
5.3 Installing Optical Fibers Between BBU and RSU
Prerequisite
l
The ESD wrist strap must be worn.
l
The baseband power cabinet and the RF cabinet have been independently installed.
Context
When the baseband power cabinet and the RF cabinet are installed side by side or they
are far away from each other, you need to connect BBU and RSU using optical fibers.
Pay attention to the following points when installing optical fibers:
l
Do not damage the optical fiber cladding during operations.
l
Protect optical fiber connectors and avoid contaminating them.
l
Do not forcibly bundle optical fibers.
l
Curve optical fibers at the turning.
Steps
1.
Affix a temporary label.
5-10
SJ-20101019140047-002|2012-03-15 (R1.1)
ZTE Proprietary and Confidential
Summary of Contents for ZXSDR RSUC
Page 4: ...II ...
Page 6: ...II ...
Page 8: ...II ...
Page 52: ...Figures This page intentionally left blank ...