Chapter 2 Alarm
Sub-code Description
Each sub-code represents a slot.
Effect on the System
The system heat dissipation performance is affected, which may cause error codes.
Possible Causes
1.
The working temperature is too high.
2.
The fan is set to a low position or cannot work properly.
3.
The board hardware is faulty.
Handling Procedure
1.
Check whether the working temperature of the equipment room.
l
If yes, check and ensure that the cooling devices are working properly.
l
If no, go to step 2.
2.
Check whether there are alarms related to fan operations.
l
If yes, select
Setup > Shelf > Fan
and check whether the fans are set to a low
shift position. If yes, set the fans to a high shift position.
l
If the alarm persists, check whether the fans fail to work. If yes, replace the fans.
3.
If the alarm persists after the preceding steps, it indicates that the board in the
corresponding slot is faulty. Replace the board.
2.4.5 4001 Outdoor temperature alarm
Alarm Property
l
Alarm Code: 4001
l
Alarm Information: The temperature of the outdoor monitoring device is abnormal.
l
Alarm Level: Major
l
Alarm Type: Environment Alarm
Sub-code Description
l
Sub-code 1: The temperature is low.
l
Sub-code 2: The temperature is high.
l
Sub-code 3: The temperature is invalid.
Effect on the System
The outdoor monitoring device is abnormal. It does not affect the system performance.
Possible Causes
The temperature of the outdoor monitoring device is abnormal.