ZXMW NR8250 Alarm and Notification Handling Reference
l
Sub-code 3:
The standby patch package of the active software package
synchronization failure
l
Sub-code 4: The standby BBU's software package synchronization failure
l
Sub-code 5: The running patch package of the standby software package synchroni-
zation failure
l
Sub-code 6:
The standby patch package of the standby software package
synchronization failure
l
Sub-code 13: The firmware package synchronization failure
l
Sub-code 14: The hot patch package synchronization failure
l
Sub-code 15: Files under BIN directory synchronization failure
l
Sub-code 16: Files under INF directory synchronization failure
Effect on the System
l
Case 1: If active/standby changeover does not occur, the system services are not
affected, but the system reliability is affected, that is, the active/standby changeover
is disabled.
l
Case 2: After active/standby changeover occurs, the boards related to the software
cannot operate properly, and the services carried by the board are interrupted.
Possible Causes
The standby board fails to synchronize files with those in relevant directories at the active
board.
Handling Procedure
1.
In the software version management window, select
Maintenance > Version > IDU
and check whether the software version is correct.
l
If no, download the correct version package.
l
If yes, go to step 2.
2.
Reset the standby board.
2.3.7 6204 Board software fault
Alarm Property
l
Alarm Code: 6204
l
Alarm Information:
When the controlled board fails to load or download the
CPU/FPGA software, the alarm is reported.
l
Alarm Level: Major
l
Alarm Type: Handling Alarm
Sub-code Description
l
Sub-code 1: Failed to load CPU software
l
Sub-code 2: Failed to load FPGA software
2-64
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential