RSU82 User Manual
Note:
l
If the RSU82 is installed in the BS8800 cabinet, the feeder is led out from the
cabling trough at the cabinet top.
l
If the RSU82 is installed in the BS8900 cabinet, the feeder is led out from the
cabling hole at the cabinet bottom.
– End of Steps –
4.3.4 Installing an SFP High-Speed Cable
This procedure describes how to install an SFP high-speed cable. The SFP high-speed
cable is used to exchange signals between the RRUs and BBU or cascade the RRUs.
Prerequisite
l
The ESD wrist strap is worn.
l
The RSU82 is installed successfully.
Steps
l
Remove the dustproof cap from the TX1/RX1 interface on the RSU82 module, and
insert the SFP high-speed cable into the TX1/RX1 interface until a "click" sound is
heard, as shown in
4-6
SJ-20111021104623-005|2012-12-20 (R1.5)
ZTE Proprietary and Confidential