Hardware Development Guide of Module Product
All Rights reserved, No Spreading abroad without Permission of ZTE
10
ZTE MG2618
3
Electric Features
This chapter mainly describes the module’s electrical characteristics, incl
uding the level, power
consumption, reliability of module’s interfaces.
3.1
Interface Power Level
Table 3
–
1 Power Level Range of Digital Signal
Interface
High/Low level
Min.
Typ.
Max.
Remark
UART
0
0
0
0.3* UART1
2.8V
0.7* UART1
2.8V
1.1*UART1
SIM
0
0
0
0.3*VREG_SIM
1.8V/3.0V
0.7*VREG_SIM VREG_SIM
1.1*VREG_SIM
The high power level of UART1 is 2.8V, VREG_SIM is 1.8V/3V( automatic adaptation).
3.2
Power Consumption
Table 3
–
2 Power Consumption of Module (Typical)
Test Items
Test condition(Test duration
1min)
Test result
Unit
GSM
GPS
Max.
Min.
Average
Standby/sleep current
Standby
The kernel is
running, but not
working properly
47.46
30.32
31.16
mA
Standby
ON
69.19
44.45
46.35
mA
Standby
OFF
39.45
21.96
22.87
mA
Sleep
ON
75.2
23.68
27.2
mA
Sleep
OFF
28.55
0.93
2.45
mA
Working current
Turn on the module, GSP
kernel is running, not sleep or
work
123.44
54.27
72.55
mA
Network lock current
PGSM
,
62
,
PCL5
239.4
174.68
242.68
mA