background image

INSTALLATION

It is essential to install the unit properly to ensure safe and reliable operation. Please read through all instructions thoroughly and 
carefully before installing the unit. The correct mounting and wiring is the key to the effectiveness of SW830 switch. Installers must 
read and follow installation instructions and warnings in the manual from original manufacturer. The vehicle operator should verify this 
system is fastened to the vehicle securely and is functioning properly. Failure to follow all safety precautions and instructions may void 
warranties, cause personal injury and/or vehicle damage, including fire.

MOUNTING

Mount the power module in a location that is not exposed directly to weather elements such as the driver compartment firewall, below 
the seat, or in the trunk; and away from any air bag deployment areas. Ensure that all wiring harness connections are made prior to 
connecting the harness to the power module.

Assemble the included panel stand and secure it onto a desired smooth surface via suction cup, where it can be easily accessed by 
the vehicle operator. If no smooth surface is present, use the included adhesive base to assist the mounting; ensure that the surface 
is cleaned thoroughly before applying the adhesive base onto the mounting surface. Leave adhesive to set for at least 24hr before 
mounting the suction cup on to the base. Once the mounting stand is fitted, secure the control panel tightly onto the stand. 

WARNING:

 

Do not interfere with the proper operation of the vehicle airbag deployment system.

Note:

 

Avoid mounting the switch unit with wiring harness exiting downward. This may cause harness connection to fall off during   

           harsh or sudden impact.

SW830

Multi-purpose Switch / Control 

Panel w/ Power Module

PROGRAMMING (Cont’d)

Mutually Exclusive Control:

Button B1~B3 or Button B1~B4 maybe grouped for mutually exclusive control. Only one of the buttons may be turned ON at a time.
1. Press and hold 

B1

 and 

B4

 for 3 seconds to enter PROGRAMMING MODE.

    Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B1 or B2 for 3 seconds to turn ON/OFF its green backlit.

3. Once set, press and hold 

B1

 and 

B4

 for 3 seconds to exit PROGRAMMING MODE.

Note: 

While in mutually exclusive group, Button B2 will active all SW1, SW2 & SW3 connection together.

 

When configuring as Mutually Exclusive Group, these buttons must be configured as “ON/OFF switch”. 

European Siren Interlock:

The Button B5 and B6 may be configured so that Button B5 turns Button B6 OFF when deactivated and turn itself ON when Button 
B6 is activated. This configuration is commonly used for that Button B5 is used as the primary visual warning device and Button B6 
is use as a siren activation.
1. Press and hold 

B1

 and 

B4

 for 3 seconds to enter PROGRAMMING MODE.

    Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B6 for 3 seconds to turn ON/OFF the green backlit.

3. Once set, press and hold 

B1

 and 

B4

 for 3 seconds to exit PROGRAMMING MODE.

Note: 

When configuring as Button mapping mode, Button B5 and Button B6 must be configured as “ON/OFF switch”.

Button Mapping:

Button B7 may be set to activate and deactivate by Button B5.
1. Press and hold 

B1

 and 

B4

 for 3 seconds to enter PROGRAMMING MODE.

    Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B5 for 3 seconds to turn ON/OFF the green backlit.

3. Once set, press and hold 

B1

 and 

B4

 for 3 second to exit PROGRAMMING MODE.

Note:

 

When configuring as Button mapping mode, Button B5 and Button B7 must be configured as an “ON/OFF Switch”.

LED Signal Display Mode Change:

The 10-LED Signal Display may display either the Lightbar flash signal or the 

directional / warning advisor

 flash signal. To change 

the display mode: 
1. Press and hold 

B1

 and 

B4

 for 3 seconds to enter PROGRAMMING MODE.

    Top Left LED Indicator x4 will light to indicate that you are in PROGRAMMING MODE.
2. While in PROGRAMMING MODE, press Button B8 to turn ON/OFF the red backlit.

3. Once set, press and hold 

B1

 and 

B4

 for 3 seconds to exit PROGRAMMING MODE.

Green Backlit

Button B1 ON
Button B2 ON

Button B1~B3
Button B1~B4

Mutually Exclusive Group

Button B1&B2 OFF

Independent Controlled (default)

Button B6 Green Backlit

OFF

ON

Interlock OFF (default)

Interlock ON 

Mode

Button B8 Red Backlit

OFF

ON

Lightbar flash signal

Directional / warning advisor

flash signal (default)

Mode

Button B5 Green Backlit

OFF

ON

No Button Mapping (default)

Button B7 Mapped with Button B5

Mode

Power Module

Control Panel

- 1 -

- 4 -

171226A03

Application Example

Application Example

Application Example

Reviews: