background image

FM2748

1019

Supersedes

0617

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

Flushing/Descaling Procedures

  1.  Follow and understand all safety related information provided with the tankless 

water  heater  as  well  as  the  flushing  system  before  starting  the  flushing 

operation.  Wear appropriate safety apparel including safety glasses and 

rubber gloves.  Inspect all hoses and electrical cords for any kinks, cuts, 

etc. that could result in an electrical shock hazard or fluid leakage.  Replace 

any worn or damaged components.  Consult appliance instruction manual 

for complete flushing instructions.

  2.  Disconnect power to the tankless water heater, following the instructions 

provided with the appliance.

  3.  Drain the water heater following the instructions provided with the appliance.
  4.  Close the Cold Water Supply Valve and Water Heater Outlet Valve, isolating 

the heat exchanger.

  5.  Connect a hose (supplied with the system) from the fitting labeled  “Pump 

Discharge” on top of the Flushing System to the Service Valve on the Cold 

Water Supply side of the water heater.

  6.  Connect a hose (supplied with the system) from the fitting labeled “Return” 

on 

top of the Flushing System to the Service Valve on the Hot Water outlet side 

of the water heater.

  7.  Remove the black threaded cap on top of the system and add no more than 2 

gallons of virgin food grade white vinegar to the tank.  Replace the threaded 

cap.  Make sure the included o-ring is properly seated in the cap to provide a 

leak proof seal.

  8.  Open the Hot and Cold Service Valves to the water heater heat exchanger.
  9.  Plug  Power  Cord  from  the  Flushing  System  Pump  to  a  properly  grounded 

electrical receptacle.  Never allow the pump to run without adequate liquid 

in the tank or possible damage to the pump may occur.

 10.  Allow  the  pump  to  circulate  the  vinegar  solution  for  at  least  45  minutes 

or per the appliance manufacturer’s recommendation (consult appliance 

instruction manual).  Monitor the system for leaks or any peculiar behavior.  

Unplug the power cord if the pump stops, an external leak develops, or the 

flow is greatly reduced.

 11.  After the required time expires, unplug the power cord from the receptacle.
 12.  Close the Service Valve on the Cold Water Supply line and disconnect the 

hose end from the Service Valve.

 13.  Disconnect the hose end from the Flushing System “Return” Line Connection 

and route it to a suitable drain or to a bucket.  Connect an extra length of hose 

if necessary.

 14.  Open the Cold Water Supply Valve to flush the water heater with fresh water, 

rinsing out the cleaning solution.  Let the system flush for 5 minutes or as 

required per the appliance instructions.  Monitor the discharge from the 

hose.  If using a bucket, empty as needed.

 15.  After the required time expires, close the Hot Water Service Valve and 

disconnect 

the hose.

 16.  Open the Hot Water Supply Valve.
 17.  Restore power to the heater system and return it to service.

After completing the flushing operation:

  1.  Discard the contents of the Flushing System by removing the threaded cap 

from one of the tank access connections on the top or side of the tank.  Pour 

the contents into a suitable drain.

  2.  Remove  the  Return  fitting  from  the  top  of  the  tank  to  access  the  strainer 

assembly.  The strainer element is connected to the fitting with a hose clamp.  

Loosen the clamp to remove the strainer.  Discard the contents of the strainer 

and rinse away any remaining particles.  Inspect the strainer for any tears or 

damage.  Replace the strainer as needed.  Order P/N 150786.  Re-assemble 

the strainer to the fitting assembly and tighten clamp.

  3.  Replace the fitting assembly into the cover of the tank.
  4.  Add approximately one gallon of fresh water to the tank.  Connect a hose 

to the 

Pump Discharge connection and route to a suitable drain.  Plug in the pump 

to flush the vinegar solution out of the pump.  Pour any remaining liquid from 

the tank and replace threaded caps.

  5.  Store the pump system in an appropriate location to prevent damage by 

impact 

and temperature extremes.

TANKLESS

WATER

HEATER

HOT WATER SERVICE VALVE

120 V OUTLET

RETURN LINE

PUMP 
POWER
CORD

TANK ACCESS
CONNECTIONS

STRAINER 
ELEMENT

PUMP

SCALE REMOVAL SYSTEM

HANDLE

PUMP DISCHARGE LINE

HOT WATER OUT

COLD WATER IN

COLD WATER
SUPPLY VALVE

COLD WATER
SERVICE VALVE

WATER HEATER

OUTLET VALVE

SK2793

Water heater connections may vary.  Consult appliance 

owner's manual for actual connection locations.

SRS

SCALE
REMOVAL
SYSTEM

®

 INSTALLATION INSTRUCTIONS 

PREINSTALLATION CHECKLIST

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

P/N 152644

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

Patent No. 

9,228,575

Reviews: