background image

FM2102

1207

Supersedes

1107

NOTICE TO INSTALLER:  Instructions must remain with installation.

  Congratulations on the purchase of the Zoeller  
Ef

fl

 uent Turbine Submersible Pump. For over sixty years the name 

Zoeller has rep re sent ed the standard for sub mers ible sump and 
sew age pumps. The same high quality workmanship and easy 
maintenance design has been incorporated into this line of on-site 
waste wa ter products. This Zoeller system will provide years of 
trou ble-free service when installed according to the manufacturer 
recommendations.

Owner’s Information

Model Number:

 ______________________

 Date Code:

   _________________

Job Name:  ______________________________________________________ 

Dealer:

   _________________________________________________________

Date of Purchase:  _______________________________________________

Contractor:

 _____________________________________________________

Date of Installation:

  _______________________________________________

System Readings During Operation:  Voltage

 __________

 Amps  _________

ZOELLER ON-SITE WASTEWATER PROD UCTS

OWNER’S MANUAL

Ef

fl

 uent Turbine Submersible Pumps

Safety Instructions

  This manual in cor po rates the in stal la tion, operation, main te nance, 
and service instructions into one doc u ment to aid in the own er ship 
of a Zoeller on-site wastewater product. Please read and review this 
manual be fore in stall ing the product. Many items con tained within, 
when fol lowed correctly, will not only ensure a long and problem-free 
life for the system, but also save time and money during in stal la tion. 
Should further as sis tance be nec es sary please call our Tech ni cal 
Service de part ment at 1-800-928-PUMP.

Safety Instructions .......................................................................... 1
Limited Warranty............................................................................. 2
Preinstallation Information .............................................................. 2
Pump Performance Data .............................................................3-4
Electrical Data  ............................................................................... 5
Major Components  ........................................................................ 5
Pump Installation and Wiring Diagram ........................................... 6
System Wiring Instructions ............................................................. 6
Splicing Underground Wires ........................................................... 7
Start-up and Maintenance .............................................................. 7
Troubleshooting & Service Checklist .............................................. 7
Typical Installations  ....................................................................... 8

Table of Contents

Product information presented 

here re 

fl

 ects con di tions at time 

of  publication. Consult factory 

re gard ing  dis crep an cies  or 

in con sis ten cies.

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

© Copyright 2007 Zoeller Co. All rights reserved.

020216

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MA JOR 
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY      
INSTRUCTIONS IN MANUAL AND ON PUMP.

THIS MANUAL IS INTENDED TO ASSIST IN THE IN STAL LA TION 
AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH 
THE PUMP.

This is a 

SAFETY ALERT SYMBOL.

When you see this symbol on the pump or in the 
man u al, look for one of the following signal words 
and be alert to the potential for personal injury or 
property damage.

Warns of hazards that 

WILL

 cause serious personal    

injury, death or major property damage.

Warns of hazards that 

CAN 

cause serious personal 

injury, death or major property damage.

Warns of hazards that 

CAN 

cause personal injury 

or prop er ty damage.

Indicates special instructions which are very
important and must be followed.

THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS 
PRIOR TO PERFORMING ANY WORK ON THIS PUMP.

MAINTAIN ALL SAFETY DECALS.

Summary of Contents for FM2102

Page 1: ...tion Should further assistance be necessary please call our Technical Service department at 1 800 928 PUMP Safety Instructions 1 Limited Warranty 2 Preinstallation Information 2 Pump Performance Data 3 4 Electrical Data 5 Major Components 5 Pump Installation and Wiring Diagram 6 System Wiring Instructions 6 Splicing Underground Wires 7 Start up and Maintenance 7 Troubleshooting Service Checklist 7...

Page 2: ...er sufficient voltage to the pump motor But more important they could present a safety hazard if the insulation were to become damaged or the connection end were to get wet 7 Make sure the pump electrical supply circuitisequippedwithfusesorcircuitbreakersofproper capacity A separate branch circuit is recommended and Limited Warranty Manufacturerwarrants tothepurchaserandsubsequentownerduring thewa...

Page 3: ...401 ft 122 2m Liters Gal 3 4 HP 120 36 6 80 24 4 11 6 43 9 13 1 49 6 13 0 49 2 14 1 53 4 40 12 2 14 5 54 9 1 2 HP 7 STAGE 360 400 26 9 36 3 7 6 240 160 200 48 8 73 2 61 2 0 9 6 7 1 44 7 40 1 35 2 9 3 11 8 10 6 280 85 3 28 8 7 6 104 112 120 360 109 7 3 2 12 1 21 2 5 6 97 5 320 3 4 HP 10 STAGE 7 STAGE Liters 177 ft 54 0m 9 4 5 5 Gal 12 1 14 4 35 6 20 8 45 8 54 5 1 2 HP 5 STAGE 1 2 HP 5 STAGE 440 480...

Page 4: ...2 3 35 9 Gal 135 9 129 5 122 3 Liters 3 4 HP 5 10 20 15 25 30 35 40 0 20 40 60 80 100 140 120 20 140 40 60 80 100 120 0 8 16 24 32 40 180 220 200 160 240 48 56 64 72 54 9 180 220 200 67 1 61 140 160 42 7 48 8 77 6 20 5 51 9 13 7 7 1 17 2 26 9 65 1 22 3 18 7 84 4 70 8 98 4 88 6 26 23 4 1 2 HP 4 STAGE 3 4 HP 6 STAGE 1 HP 7 STAGE 4 STAGE 6 STAGE 7 STAGE 129 8 124 5 120 4 Liters 137 4 141 6 311 Ft 94 ...

Page 5: ...ine pumps are nonautomatic The use of float switches are required for the proper operation of the pump Operation of these pumps without float switches can result in failure of the pump and void the warranty A minimum of two float switches should be used in each application A pump control float switch A high water alarm float switch 4 Piping The submersible effluent turbine pump can be installed wi...

Page 6: ...gram with the alarm for installation and check your local codes 9 Runtheappropriatepowertothecontrolpanelfromafused circuit breaker disconnect The appropriate power supply information may be found on the pump nameplate 10 To provide a suitable ground a separate ground wire green or bare at least as large as the line conductors is required It is connected from the electrical disconnect box to the c...

Page 7: ...nections Make sure the weep hole is clear Make sure the float switches are free to move within the basin Make sure there are no leaks in the plumbing Make sure there is no excessive noise while the pump is running ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are not standing in water and wearing insulated protective ...

Page 8: ...Manufacturers of www zoeller com Typical Installations ALL INSTALLATIONS REQUIRE A FILTER BEFORE THE PUMP SK2220 SK2219 ZOELLER EFFLUENT TURBINE PUMP WARNING P N Z ZOELLER SEPTIC TANK SEPTIC TANK ZOELLER EFFLUENT TURBINE PUMP WARNING ELECTRICAL SHOCK HAZARD Z C O Z P N 10 1193 REV A 0ELLER PUMP CO LOUISVILLE KY NOTE Flow must be directed around the motor for cooling on 2 HP and higher units ...

Reviews: