ELECTRICAL PRECAUTIONS

  Before servicing a pump, always shut off the main power breaker to the panel and then disconnect the 

pump - making sure you are wearing insulated protective sole shoes and are not standing in water. Under flooded conditions, contact your local electric 

company or a qualified licensed electrician for disconnecting electrical service prior to pump removal. 

 Submersible pumps contain oils which become pressurized and hot under operating conditions - 

allow 2-1/2 hours after disconnecting before at-

tempting service.

CONDITION

A.   Pump will not start or run.

 

          COMMON 

CAUSES

B.  Motor overheats and trips overload or blows fuse.

 

-  Incorrect Voltage

 

-  Unbalanced power source

 

-  Incorrect motor rotation

 

-  Negative or low head

 

-  Excessive water temperature

 

-  Impeller or seal mechanically bound

 

-  Defective capacitor or relay

 

-  Motor shorted

 

-  Lost one line in a Three Phase unit

C.   Pumps starts and stops too often.

 

- Check valve stuck open

 

-  Level controls out of adjustment

 

-  Temperature sensor tripping

 

- Thermal overload switch out of 

 

  adjustment or defective

 

- Pit too small

D.   Pump will not shut off.

 

-  Debris under float switch

 

-  Float travel obstructed

 

-  Defective or damaged float switch 

 

-  Magnetic starter contacts shorted

 

-  Air lock - check vent hole

E. Pump operates but delivers little or no water.

 

-  Check for plugged Pump housing, discharge    

 

  pipe or sticking check valve

 

-  Vent hole clogged or not drilled

 

-  Discharge head exceeds pumps capacity

 

-  Low or incorrect voltage

 

-  Incorrect motor rotation

 

-  Defective capacitor

F.   Drop in head and/or capacity after a period or use.

 

-  Increase Pipe Friction

 

-  Clogged line or check valve

 

-  Abrasive material & chemical, 

 

  deteriorated impeller and pump housing

If the above check list does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump.

Service Checklist & Trouble Shooting

 

Steps 

Check Voltage At 

If No Voltage 

If Voltage

 

No. 1 

Line terminals in pump’s 

Check Disconnect switch, line 

Proceed to No. 2

 

 

control panel 

fuse, and/or circuit breakers 

  

L

1

 - L

2

 - L

3

 (3 Phase) 

in power supply circuit.

 

No. 2 

Pump motor terminals in 

Check for control circuit 

Check starting relay 

 

 

pump’s control panel  

voltage. Check out magnetic 

and capacitor (1 

  

T

1

 - T

2

 - T

3

 

starter contacts, thermal 

phase units). Check

    

 

overloads, and float switches 

pump for ground, 

 

 

 

 

and binding impeller

© Copyright 2021 Zoeller

®

 Co. All rights reserved.

Summary of Contents for 61 HD Series

Page 1: ...60 for repair manual on 61 HD Series Pumps Should further assistance be necessary please call our Technical Service Department at 1 800 928 PUMP 7867 Table of Contents Safety Instructions 1 Limited Wa...

Page 2: ...manufactured at Zoeller Engineered Product s option provided however that by so doing we shall not be obligated to replace an entire assembly the entire mechanism or the complete unit Major components...

Page 3: ...it be 36 or larger in diameter 3 INFORMATION VENT HOLE PURPOSE It is necessary that all submersible pumpscapableofhandlingvarioussizesofsolidwastebeofthebottomintake design to reduce clogging and seal...

Page 4: ...t gases and odors to the atmosphere through vent pipe per local and state codes 8 Secure power cord to avoid entanglement with variable level float switch mechanism 9 Do not reduce pump discharge pipe...

Page 5: ...and white wires The VOM should read approximately 330k Ohms Resistance readings significantly lower indicate a seal leak with water in the seal chamber If VOM reading is open then a problem exists wi...

Page 6: ...d must be hooked up to validate warranty The sensors must be specified at time of initial pump order and are not available for field installation Sensor wire colors are as shown N C SENSOR 330K OHMS R...

Page 7: ...a system is shutdown for more than six months the following is recommended Pumps If pit is to remain dry then the pump can remain in the pit With the pump in the pit it should be operated for five min...

Page 8: ...ll not shut off Debris under float switch Float travel obstructed Defective or damaged float switch Magnetic starter contacts shorted Air lock check vent hole E Pump operates but delivers little or no...