DRAIN PUMP SYSTEM
MODEL132 (Preassembled)
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
P/N 015765
SECTION: 6.10.046
FM2113
1012
Supersedes
0111
Notice to Installer: Instructions must remain with installation.
© Copyright 2012 Zoeller Co. All rights reserved.
When making changes to this FM, be sure to also make changes to FW0107 if the 104 pump is changed.
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
DO NOT
remove
the test plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained
for future reference.
1. To reduce the risk of electrical shock, a properly grounded receptacle of
grounding type must be installed and protected by a ground fault circuit
interrupter (GFCI) and in accordance with National Electrical Code and
local codes.
(SEE WARNING BELOW).
2. Make certain that the receptacle is within the reach of the pump’s power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords
that are too long or too light do not deliver sufficient voltage to the pump
motor. But more important, they could present a safety hazard if the
insulation were to become damaged or the connection end were to fall
into the sump.
3. Testing for Ground. As a safety measure, each electrical outlet should
be checked for ground using an Underwriters Laboratory Listed circuit
analyzer which will indicate if the power, neutral and ground wires
are correctly connected to your outlet. If they are not, call a qualified
electrician.
4. For Added Safety. Pump must be connected to a 3-prong grounded
outlet interrupter device (ground fault circuit interrupter).
5.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM
ITS POWER SOURCE BEFORE HANDLING.
Single phase pumps
are supplied with a 3-prong grounded plug to help protect you
against the possibility of electrical shock.
DO NOT, UNDER ANY
CIRCUMSTANCES, REMOVE THE GROUND PIN
. To reduce the risk
of electrical shock, a properly grounded receptacle of grounding type
must be installed and protected by a ground fault circuit interrupter
(GFCI) in accordance with national electrical code and local codes.
6. Installation and checking of electrical circuits and hardware should only
be performed by a qualified licensed electrician.
7. Risk of electric shock - These pumps have not been investigated for
use in swimming pool areas.
8. According to the state of California (Prop 65), this product contains
chemicals known to the state of California to cause cancer and birth
defects or other reproductive harm.
1. Check to be sure your power source is adequate for handling the voltage
requirements of the motor, as indicated on the pump or basin plate.
2. Make sure the pump electrical supply circuit is equipped with fuses
or circuit breakers of proper capacity. A separate branch circuit is
recommended, sized according to the National Electrical Code for the
current shown on the pump name plate.
3. All plumbing (discharge and vent lines) must be installed to meet
local codes. Unit must be vented. Some states require this unit to be
installed by a qualified licensed plumber.
DO NOT USE AN AUTOMATIC
PLUMBING VENT DEVICE SIMILAR TO A "PRO-VENT"
.
4. Repair and service should be performed by Zoeller Pump Company
Authorized Service Station only.
5. CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY
CYCLING OF PUMP.
6. Dewatering pumps are not designed or intended for handling
raw sewage.
7. Maximum operating temperature for 132 Drain Pumps must not exceed
110°F (43°C).
8. For health reasons, do not unplug, turn off, or disable pump and use
pump tank system as a way to fill up a sink or laundry tray, etc.
NOTE:
Pumps with the "UL" mark and pumps with the "US" mark are
tested to UL Standard UL778. CSA Certified pumps are certified to CSA
Standard C22.2 No. 108.
SEE BELOW FOR LIST OF WARNINGS
SEE BELOW FOR LIST OF CAUTIONS
MODEL: ______________________
DATE CODE: __________________
DATE INSTALLED: _____________
REFER TO WARRANTY ON PAGE 2.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.