background image

DRAIN PUMP SYSTEM 

MODEL132 (Preassembled) 

 

INSTALLATION INSTRUCTIONS 

PREINSTALLATION CHECKLIST

 

P/N 015765

SECTION: 6.10.046

FM2113

1012

Supersedes

0111

Notice to Installer:  Instructions must remain with installation.

© Copyright 2012 Zoeller Co. All rights reserved.

When making changes to this FM, be sure to also make changes to FW0107 if the 104 pump is changed.

1.   Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact  your dealer before using.  

DO NOT

 remove 

the test plugs from the pump.

2.  Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained 

for future reference. 

1.  To reduce the risk of electrical shock, a properly grounded receptacle of 

grounding type must be installed and protected by a ground fault circuit 

interrupter (GFCI) and in accordance with National Electrical Code and 

local codes. 

(SEE WARNING BELOW). 

2.  Make certain that the receptacle is within the reach of the pump’s power 

supply cord. DO NOT USE AN EXTENSION CORD.  Extension cords 

that are too long or too light do not deliver sufficient voltage to the pump 

motor. But more important, they could present a safety hazard if the 

insulation were to become damaged or the connection end were to fall 

into the sump. 

3.  Testing for Ground. As a safety measure, each electrical outlet should 

be checked for ground using an Underwriters Laboratory Listed circuit 

analyzer which will indicate if the power, neutral and ground wires 

are correctly connected to your outlet. If they are not, call a qualified 

electrician. 

4.  For Added Safety. Pump must be connected to a 3-prong grounded 

outlet interrupter device (ground fault circuit interrupter). 

5.

  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM 

ITS POWER SOURCE BEFORE HANDLING. 

 Single phase pumps 

are supplied with a 3-prong grounded plug to help protect you 

against the possibility of electrical shock. 

 DO NOT, UNDER ANY 

CIRCUMSTANCES, REMOVE THE GROUND PIN

.  To reduce the risk 

of electrical shock, a properly grounded receptacle of grounding type  

must be installed and protected by a ground fault circuit interrupter 

(GFCI) in accordance with national electrical code and local codes.

6.  Installation and checking of electrical circuits and hardware should only 

be performed by a qualified licensed electrician.

7.  Risk of electric shock - These pumps have not been investigated for 

use in swimming pool areas.

8.  According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and birth 

defects or other reproductive harm.

1.  Check to be sure your power source is adequate for handling the voltage 

requirements of the motor, as indicated on the pump or basin plate. 

2.  Make sure the pump electrical supply circuit is equipped with fuses 

or circuit breakers of proper capacity. A separate branch circuit is 

recommended, sized according to the National Electrical Code for the 

current shown on the pump name plate. 

3.  All plumbing (discharge and vent lines) must be installed to meet 

local codes. Unit must be vented. Some states require this unit to be 

installed by a qualified licensed plumber.

 DO NOT USE AN AUTOMATIC 

PLUMBING VENT DEVICE SIMILAR TO A "PRO-VENT"

4.  Repair and service should be performed by Zoeller Pump Company 

Authorized Service Station only.

5.  CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY 

CYCLING OF PUMP.

6.  Dewatering pumps are not designed or intended for handling 

raw sewage. 

7.  Maximum operating temperature for 132 Drain Pumps must not exceed 

110°F (43°C).

8.  For health reasons, do not unplug, turn off, or disable pump and use 

pump tank system as a way to fill up a sink or laundry tray, etc.  

NOTE:

 Pumps with the "UL" mark and pumps with the "US" mark are

tested to UL Standard UL778. CSA Certified pumps are certified to CSA

Standard C22.2 No. 108.

SEE BELOW FOR LIST OF WARNINGS

SEE BELOW FOR LIST OF CAUTIONS

MODEL:  ______________________

DATE CODE:  __________________

DATE INSTALLED:   _____________

REFER TO WARRANTY ON PAGE 2.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

Summary of Contents for 132

Page 1: ... fault circuit interrupter GFCI in accordance with national electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been investigated for use in swimming pool areas 8 According to the state of California Prop 65 this product contains chemicals known to ...

Page 2: ... every new product to be free from defects in material and workmanship under normal use and service when properly used and maintained for a period of one year from date of purchase by the end user or 18 months from date of original manufacture of the product whichever comes first Parts that fail within the warranty period one year from date of purchase by the end user or 18 months from the date of...

Page 3: ...llation of the drain system The actual configuration will vary depending on your cabinet and sink configuration Figure 1 STANDARD INSTALLATION 1 DO read all installation material included with the pump 2 DO inspect unit for any visible damage caused by shipping Contact dealer if unit appears to be damaged 3 DO always disconnect pump from power source before handling DO always connect to a separate...

Page 4: ...n Seal 1 N A N A 8 Unicheck 1 30 0181 019768 9 20X1 lg RHM Screw S S 8 N A N A 10 Flat Washer S S 16 N A N A 11 20 Hex Hd Nut S S 8 N A N A 12 Pipe Cap w o ring 1 N A N A 13 O Ring 1 N A N A SK2832 REV A REV B 1 9 10 11 2 6 3 5 7 8 4 12 13 Figure 2 Drain Pump 132 SK2833 STEP 3 Initial Testing of Drain Basin System 1 Plug the cord into a properly grounded GFCI receptacle 2 Fill the basin with 2 3 g...

Reviews: