18 in.
10 in.
1-1/2-in
Discharge
pipe
Check valve
Additional
3/16-in
Vent hole
Vent hole
located in
the pump
housing
GFCI outlet
Basin cover
Fill with
water
1. Place pump in a sump basin that is at least 10 in wide
and 18 in deep.
2. Install rigid 1-1/2 in discharge pipe, union, check
valve according to code.
3. Drill a 3/16 in hole in the discharge pipe, level with the
top of pump. Pumps have a vent located in the pump,
but an additional vent hole is recommeded. Connect
remaining discharge pipe into main discharge line.
4. Connect pump power supply to a GFCI-protected
receptacle.
5. Fill the basin with water to check operation. Install a
basin cover and gasket on top of the basin.
SW1311Q A
QUICK REFERENCE GUIDE.
SEE INSTRUCTION MANUAL
FOR COMPLETE DETAILS.
WARNING:
FOR YOUR PROTECTION, ALWAYS DISCONNECT
PUMP FROM POWER SOURCE BEFORE HANDLING.
SUBMERSIBLE
SUMP PUMP
MODEL #1052Q, 1096Q
Zoeller
®
is a registered trademark of Zoeller Co.
All Rights Reserved.
English Toll Free Help Line
1-800-584-8089
ZoellerAtHome.com