READ ALL INSTRUCTIONS BEFORE INSTALLING - ALL APPLICATIONS

 

Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. A separate 

branch circuit is recommended, sized according to the National Electrical Code for the current shown on the pump name plate. 

 

FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING

Single phase 

pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock.

 DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE  THE GROUND PIN

.

 

The 3-prong plug must be inserted into a 

mating 3-prong grounded receptacle. If the installation does not have such a receptacle, it must be changed to the proper type, wired 

and grounded in accordance with the National Electrical Code and all applicable local codes and ordinances.

NOTICE TO INSTALLER: Instructions must remain with installation.

FM3087

1021

Supersedes

1018

CAUTION

   

The 10-4660 water level floatless switch is designed for use with the appropriate voltage and horsepower, nonautomatic, 

single phase Zoeller pumps.

CAUTION

   

Maximum temperature must not exceed 122 °F (50 °C). NOTE: cULus code approval. NOTE: Consult factory for controlling 

units over 1/2 HP with variable level float switch.

ZOELLER FLOATLESS WATER LEVEL SWITCH

10-4660 - 115 V / UP TO 1/2 HP - 15' (5 M) CORD  

DESIGNED FOR EFFLUENT, SEWAGE AND DEWATERING APPLICATIONS

© Copyright 2021 Zoeller

®

 Co. All rights reserved.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

INSTALLATION INSTRUCTIONS

1.  Loop provided tie strap through switch as shown in Figure 1 and 3, leaving approximately 3" of slack for ease of installation. 

2.  Lower switch into pit.

3.  Place the bottom of the switch against the discharge pipe. 

OFF

  level should be approximately 4" above the inlet of the pump. The 

ON 

level must be below the check valve, the inlet and lid of the pit.

4.  Be certain the outward face of the switch has 2" minimum clearance from any foreign objects, including the wall of the pit, the 

discharge pipe, and the pump.

5.  Securely fasten top and bottom of the switch to the discharge pipe by tightening the two tie straps.

6.  Insert the piggyback plug from the switch into a standard grounded outlet of proper voltage. 

For installation using watertight junction box, reference Figure 4.

7.  Securely tape or clamp both switch and pump cord to the discharge pipe, clear of switch range (refer to step 4).

8.  Plug sump pump into the switch's piggyback plug. See Figure 2.

9.  Clean basin free of debris after installation.

10.  Check and test your installation. Fill basin with water and allow pump to cycle to ensure proper range and operation. 

Note: The Floatless control switch needs a minimum of 2" clearance between all foreign objects in the basin / pit. The switch has a 
maximum run time of 2 minutes. Ensure your basin is appropriate before installing the Floatless switch.

FIGURE 2

MODEL NO.

SUMP

SEWAGE

X

10-4660

X

53-0084

X

98-0069

X

267-0121

X

SWITCH TYPE

POWER WIRE COLOR

SUMP

RED

SEWAGE

BLUE

DISCHARGE PIPE

CORDS SECURED TO

LEVEL

PUMP "OFF"

LEVEL

PUMP "ON"

ZOELLER UNICHECK

TO POWER SUPPLY

REDUNDANT "ON" 

LEVEL 

MOUNT FLOATLESS SWITCH 
WITH (2) TIE STRAPS THAT 

ARE PROVIDED WITH SWITCH.

PUMP PLUG

SWITCH PLUG

AUTOMATIC

OPERATION

MANUAL

OPERATION

L1

L2

SWITCH

DISCONNECT

WATERTIGHT

JUNCTION BOX

WHITE

BLACK

SEE CHART

BLACK

WHITE

WHITE

GREEN

BLACK

PUMP

FLOATLESS 

SWITCH

PART NO.

SUMP

SEWAGE

MODEL 

NO.

VOLTAGE

PHASE

10-4660

X

X

53-0084

X

LN53

115V

1

98-0069

X

LN98

115V

1

267-0121

X

LN267

115V

1

Reviews: