background image

H0590800.A - 2017/05

More documents on:

www.zodiac-poolcare.com

Z900

Instructi ons for installati on and use

 - 

English

Heat pump

Translati on of the original instructi ons in french 

EN

Summary of Contents for Z900 TD20

Page 1: ...H0590800 A 2017 05 More documents on www zodiac poolcare com Z900 Instructions for installation and use English Heat pump Translation of the original instructions in french EN...

Page 2: ......

Page 3: ...minal board or the power supply socket before connection For any component or sub assembly containing a battery do not recharge or dismantle the battery or throw it into a re Do not expose it to high...

Page 4: ...is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injur...

Page 5: ...to channel the condensation away The device must not be installed With the blowing towards a permanent or temporary obstacle awning brushwood etc less than 5 metres away Within range of water or mud j...

Page 6: ...fter the lter and before the water treatment Respect the direction of hydraulic connection A by pass must be installed to make it easier to work on the device water inlet valve by pass valve water out...

Page 7: ...r GFCI Additional protection may be required during installation to guarantee the II overvoltage category The electricity supply must correspond to the voltage indicated on the device s information pl...

Page 8: ...ion lets you manage the device remotely To do so use the remote control kit available as an accessory For the connection consult the manual supplied with the kit If a remote control device is to be in...

Page 9: ...n average 10 C at night it will be even more e ective if it runs during the warmest hours of the day Keep the evaporator clean Set the temperature you want and let the heat pump run adjusting the setp...

Page 10: ...de and close valve C by half Connect the power supply to the heat pump Press and hold for 5 seconds to start the appliance in heating mode After the start up steps for your heat pump Shut down the wat...

Page 11: ...19 and 30 on the terminal unit The device must then display in place of 2 5 2 Adjusting the temperature setpoint in cooling mode The setpoint temperature is set by default to 28 C Press for 5 seconds...

Page 12: ...y serviced at least once a year to ensure proper operation maintain performance levels and possibly prevent potential failures Depending on the legislation in the country where the device is installed...

Page 13: ...ator it will stop itself this means that the outdoor temperature is too low below 12 C The device is smoking This may occur when it is in a defrost cycle and the water is converted to gas The device i...

Page 14: ...stuck Replace the compressor Power circuit open Establish the cause of the protection intervention Make sure that there are no short circuits on the cabling and the pump motor fan compressor and trans...

Page 15: ...ensor Automatic Air inlet sensor fault Sensor is faulty or o ine Reconnect or change the sensor Automatic Pressure sensor fault Sensor is faulty or o ine Reconnect or change the sensor Automatic Defec...

Page 16: ...hat the pool lter is not clogged Air and water emulsion passed into the device Check the pool s hydraulic circuit Flow switch blocked Check the ow switch Electronic expansion valve closed Valve expans...

Page 17: ...Ambient air sensor IG General switch SC Condensation sensor IL Line switch not supplied SPR Pressure sensor KLT Compressor contact T Anti frost heating thermostat KRAP High pressure relay TR Transfor...

Page 18: ...scription or In the technical box A Z900 TD20 TD30 TD50 B 63 connector x2 90 connector x2 C Anti vibration studs x6 D Wintering cap x2 E Remote control F Lifting kit G PAC NET cleaning product supplie...

Page 19: ...water ow m h 15 20 25 Net weight bar 430 520 837 Values provided for information purposes for a maximum length of 20 metres calculation base NFC15 100 must be checked and adapted to the installation c...

Page 20: ...Z900 TD50 97 1730 546 162 211 755 2091 1183 Overall dimensions Fronts Z900 TD20 TD30 B Side Z900 TD20 TD30 Top Z900 TD20 TD30 Top Z900 TD50 Fronts Z900 TD50 Side Z900 TD50 B Base Fan Evaporator Gland...

Page 21: ......

Page 22: ...49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Trouvez plus d...

Reviews: