Power Force

EN

Instructions for installation and use

 - 

English

 

Heat pump

Translation of the original instructions in french 

H0361900_REVH - 2020/12

Summary of Contents for POWER FORCE 25

Page 1: ...More documents on www zodiac com Power Force EN Instructions for installation and use English Heat pump Translation of the original instructions in french H0361900_REVH 2020 12 ...

Page 2: ...on responsible for their safety Children must be supervised to ensure that they do not play with the appliance This appliance can be used by children under 8 and adults with impaired physical sensory or mental capabilities or who lack experience and knowledge if they are correctly supervised or have been instructed in how to use the appliance safely and understand the hazards involved User cleanin...

Page 3: ...e appliance with wet hands or if the appliance is wet Before connecting the appliance to the power supply check that the connection unit or socket to which the appliance will be connected is in good condition and shows no signs of damage or rust For any component or sub assembly containing a battery do not recharge or dismantle the battery or throw it into a fire Do not expose it to high temperatu...

Page 4: ...where the appliance is equipped with the optional pressure gauge The high pressure circuit pipes are made of copper and have a diameter equal to or greater than 1 5 8 A certificate as indicated in 2 1 in compliance with standard NF EN 10204 must be requested from the supplier and filed in the installation s technical file Technical data relative to the safety requirements of the various applicable...

Page 5: ...Maintenance 12 3 1 I Wintering 12 3 2 I Maintenance 12 Troubleshooting 13 4 1 I Device behaviour 13 4 2 I Error code display 14 4 3 I Additional menus 15 4 4 I Wiring diagram 16 Characteristics 17 5 1 I Description 17 5 2 I Technical specifications 17 5 3 I Dimensions and marking 18 Tip to make it easier to contact the retailer Write down the retailer s contact details to help you find them more e...

Page 6: ...installed In a location subject to high winds With the blowing towards a permanent or temporary obstacle window wall hedge awning etc less than 4 metres away Within range of water or mud jets sprays or run off take the effect of the wind into account Near a heat source or flammable gas Near high frequency equipment In a location where it would be subject to snow build up In a location where it mig...

Page 7: ...e installed to make it easier to work on the device Adjust the water flow with valve A and leave valves B C D and E open water entry valve by pass valve water exit valve water entry adjustment valve optional water exit adjustment valve optional minimum distance Connection to a standard filtration circuit Tip condensation drainage Caution several litres of water must be drained from your device eac...

Page 8: ...e or crush it The equipment must be connected to an earth socket The electrical connection lines must be fixed Use the gland to pass the supply cable into the device Use the supply cable RO2V type adapted for outdoor or buried use or run the cable into a protection duct with an external diameter of between 9 and 18mm We recommend burying the cable at a depth of 50 cl 85 cm under a road or path in ...

Page 9: ...ump terminal unit fuse 1 4 1 Alarm option This option enables a relay to be connected to the alarm contact to indicate a fault by remote For the connection connect the cables to terminals 5 and 6 dry contact no polarity maximum intensity 2A heat pump terminal unit alarm contact relay separate connection cable fuse 1 4 3 Remote on off control option This option enables the on off button function to...

Page 10: ...run automatic circulation for at least 12 hours day the longer this time the longer the heat pump will have enough operating range to heat up Cover the basin with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more effective if it runs during the warmest hours of the day Keep the evaporator cl...

Page 11: ...valves D and E are not present open valve A wide and close valve C by half Connect the power supply to the heat pump If the heat pump is on standby press for 3 seconds appears for 2 seconds then different software No depending on the devices for 3 seconds and the water and setpoint temperatures are displayed a 2 minute timer will start Set the temperature you want setpoint temperature After the st...

Page 12: ...the interface 2 languages available French and English Select the device s operating mode Water heating only Water heating or cooling automatic according to need The light must be fixed No water flow Water flow too low or Water flow too high or Set the rate using valve E or C if no valve E In this setting phase wait a few minutes after each valve position change for the device to balance out EN ...

Page 13: ... is recommended that the device be general serviced at least on a yearly basis to ensure proper operation maintain performance levels and prevent some potential failures These operations are carried out at the user s expense by a technician 3 2 1 User maintenance Make sure that the filter is not blocked by any foreign bodies Clean the evaporator for location see 5 3 I Dimensions and marking using ...

Page 14: ...ll stop itself this means that the outdoor temperature is too low below 12 C The device is smoking This may occur when it is in a defrost cycle and the water is converted to gas The device is not working If there is no display check the supply voltage and the F1 fuse Whenthesetpointtemperatureisreached theheatpumpstopsheating thewatertemperature is higher than or equal to the setpoint temperature ...

Page 15: ...ician Automatic if fewer than 4 faults per hour or press Cooling circuit high pressure fault Water condenser scaled up Clean the water condenser Automatic if fewer than 4 faults per hour or press Insufficient water flow Increase flow using by pass check that the pool filter is not clogged Air and water emulsion passed into the device Check the pool s hydraulic circuit Flow controller blocked Check...

Page 16: ... of information on the fan speed Call an approved technician Cut power or press Communication fault with the A3 ventilation board Poor connections Check the connections By electricity supply disconnection or automatic if the fault disappears Power supply fault Check the power supply Incorrect configuration Check the position of switches SW1 and SW2 and the JPC bridge Board out of service Replace t...

Page 17: ...t ST3 Defrost sensor 20S 4 channel valve coil ST4 Fluid line sensor A1 Regulation board ST5 Compressor backflow sensor A2 Display board V1 V11 Varistor A3 Ventilation board Z1 Filter A4 Release board BLK Black E1 High pressure switch BLU Blue E2 Low pressure switch BRN Brown F1 2A 5x20 electronic board protection fuse G Y Green Yellow F2 Compressor internal safety GRN Green J1 Flow controller GRY ...

Page 18: ...0 to 32 C Voltage 380 415 V 50Hz 380 415 V 50Hz Acceptable variation in voltage 6 during operation Pollution class I Pollution degree 2 Overvoltage category II Nominal absorbed intensity A 10 6 12 9 Maximum absorbed intensity A 14 2 18 1 Minimum cable section mm 5x4 5G4 Proof pressure bar 3 Service pressure bar 1 5 Head loss bar 0 13 Medium water flow m h 10 Values provided for information purpose...

Page 19: ...18 5 3 I Dimensions and marking Base Front panel Cover Technical access door Rear panel Column Grid User interface Pool water intake Pool water output Evaporator Gland Overall dimensions Front Side Rear ...

Page 20: ...rty of their respec tive owners Votre revendeur Your retailer Modèle appareil Appliance model Numéro de série Serial number Pour plus d informations enregistrement produit et support client For more information product registration and customer support www zodiac com ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE ...