Instructions for installation and use 
English

H03620-00.B - 2011/11 - 374274014.00

More languages on : 
www.zodiac-poolcare.com

Summary of Contents for PF Premium 6M

Page 1: ...EN PF Premium 11M TSR 11T TSR 15M TSR 15T TSR 6M 8M 11M 11T 13M Instructions for installation and use English H03620 00 B 2011 11 374274014 00 More languages on www zodiac poolcare com ...

Page 2: ...personnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid exposure to potentially dangerous parts If the device malfunctions do not attempt to repair the device yourself call your installer Before carrying out any operation on the machine check that the power s...

Page 3: ...lay of the regulator 10 5 2 Malfunctions of the device 11 5 3 FAQ 12 6 Product registration 12 7 Conformity certificate 13 Available in appendix at the end of the manual wiring diagrams dimensions description 1 Information before installation 1 1 General terms of delivery storage and transport Any equipment even carriage and packing free travels at the consignee s risk The consignee shall make res...

Page 4: ...midity of 70 according to French standard NF 414 protection class IP 24 refrigerant gas R410A refrigerant charge see product information plate class I degree of pollution 2 overvoltage category II 2 Installation Do not pick up the device using the outer casing use the base 2 1 Access to the technical compartment 2 2 Selecting an installation site The device must be installed outdoors and there mus...

Page 5: ... Hydraulic connections Check the direction of the pipework connection see Dimensions in the appendix The connection shall comprise a Ø 50 PVC rigid pipe from a by pass on the swimming pool filtration circuit after the filter and before any water treatment unit check the tightening of the hydraulic connections and for leaks PFP Hydraulic circuit pressure Connections inlet outlet Mean water flowrate...

Page 6: ...tside of the European community and with an outer diameter between 9 and 18 mm use the stuffing box to run the supply cable into the device 2 5 2 Connections the electrical supply cable must not be exposed to elements that are sharp hot or represent a crush hazard check that all cables are secure and all terminal connections are correct Loose terminals may cause the supply terminal board to overhe...

Page 7: ...minals 1 2 alarm option to connect a relay to the alarm contact thanks to a dry contact without max I polarity 2 A between terminals 5 6 remote on off control thanks to a zero potential free contact without 230 V 50 Hz polarity between terminals 7 8 3 Use 3 1 Presentation of the regulation Symbol Designation steady flashing water flow water flow rate ok water flow too weak high or absent ambient a...

Page 8: ...echnical components must be fitted set the by pass and setting valves see 2 4 as follows valve 1 completely open valves 2 3 4 5 closed The incorrect setting of the by pass valve can lead to the malfunctioning of the heat pump switch on the filter system progressively close valve 1 in order to increase the filter pressure to 150 g 0 150 bar open valves 2 3 and 4 completely then half open valve 5 se...

Page 9: ...sential due to the risk of the condenser freezing and breaking This situation is not covered by the warranty To avoid damaging the device with condensation do not cover it with an air tight cover switch the digital control panel to stand by mode by pressing for 3 seconds and cut the power supply open valve 1 close valves 2 and 3 and open valves 4 and 5 if fitted ensure that no water is flowing thr...

Page 10: ... they are securely fastened to the coolant circuit and that they cutoff the electrical circuit when tripped during maintenance work ensure there are no traces of corrosion or oil around cooling components before beginning work on the cooling circuit stop the device and wait for a few minutes before fitting the temperature and pressure sensors Some elements such as the compressor and piping may rea...

Page 11: ... several phases 1 reverse the phases on the supply terminal board without power to the device 2 3 4 contact your electricity provider to find out if modifications have been made to your equipment Switch the power supply off or press Refrigerant circuit low pressure defect Low pressure circuit pressure defect if the defect remains after reset Contact an approved technician Automatic reset for less ...

Page 12: ...Verification solution The device is not operational No display Check the supply voltage and the fuse F1 The pool temperature is above the set point temperature Increase the set point temperature A message is displayed on the screen Check the meaning of message 5 1 Absent or inadequate water flow rate Check the water flow rate by pass filtration The device is operational but water temperature fails...

Page 13: ...eck that this period has passed once the pool has reached the set point temperature the heat pump switches off check that the water temperature is lower than the requested temperature see 3 2 if the water flow rate is zero or inadequate the heat pump will stop check that water is flowing correctly through the heat pump and check the hydraulic connections when the outdoor air temperature drops belo...

Page 14: ... following products or ranges Swimming pool heat pumps Power First Premium 6M 8M 11M 11T 13M Power First Premium 11M TSR 11T TSR 15M TSR 15T TSR are in compliance with the provisions of the ELECTROMAGNETIC COMPATIBILITY directive 2004 108 EC the LOW VOLTAGE directive 2006 95 EC ...

Page 15: ...Notes ...

Page 16: ...H03620 00 B5 EN 2011 11 1 Wiring diagram PFP 6M 8M 11M 13M ...

Page 17: ...H03620 00 B5 EN 2011 11 2 PFP 11T ...

Page 18: ...H03620 00 B5 EN 2011 11 3 PFP 11M TSR 15M TSR ...

Page 19: ...H03620 00 B5 EN 2011 11 4 PFP 11T TSR 15T TSR ...

Page 20: ...oard for display C1 Fan capacitor C2 Compressor capacitor C3 Filter D1 Progressive starter H Defrost resistance HP High pressure switch LP Low pressure switch J1 Flow rate switch M1 Fan motor M2 Compressor motor MOV Expansion valve PHC Phase order controler R1 R2 Contactor ST1 Regulator sensor ST2 Anti freeze sensor ST3 Defrost sensor ST4 Liquid line sensor ST5 Compressor discharge sensor VA1 VA2 ...

Page 21: ...N 2011 11 6 Dimensions and description Base Front pannel cowl Technical door Back pannel Post Grid Regulator Ø1 water pool inlet Ø1 water pool outlet Evaporator Stuffing box PFP weight Kg 6 51 8 52 11 63 13 68 15 81 ...

Page 22: ...ct your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex France S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS Plaque signalétique Product name plate ...