Page 1: ...H0360800 E 2021 01 More documents on www zodiac com Heat Line EN Instructions for installation and use English Heat exchanger Translation of the original instructions in french...
Page 2: ...ults whose reduced physical sensoryormentalcapabilities orwhoselackofexperienceandknowledge might cause a hazard unless they have been correctly instructed to understand the safe use and hazards invol...
Page 3: ...from the power supply If the power cord is damaged it must be replaced by the manufacturer an authorised representative or a repair facility only Do not perform maintenance or servicing operations on...
Page 4: ...epending on the model 9 3 3 I Operation 10 3 4 I Additional functions 11 Maintenance 12 4 1 I Winterising 12 4 2 I Maintenance 12 Troubleshooting 13 5 1 I Appliance behaviour 13 5 2 I Error code displ...
Page 5: ...bar 0 05 0 08 0 1 Primary connection 26 34 female screw type Heat Line Plus and without circulating pump 26 34 male screw type Bare Heat Line Secondary connection PVC 50 or 63 Primary circuit operatin...
Page 6: ...ith circulating pump Plus without circulating pump Bare Multi tube exchanger body union PVC connector 63 to be glued Primary circuit drainage cap Glove finger Regulation sensor Circulating pump Exchan...
Page 7: ...the pool circuit use a system of 50 or 63 pipes if the overall length of the circuit is greater than 30 metres If the pipes are installed underground they should be in protective sleeves Preferably t...
Page 8: ...pump and the heating source If this is not possible provide a system to prevent any primary circuit water from returning to the exchanger when there is no water circulating in the secondary circuit T...
Page 9: ...ket connects are prohibited Request the installation of a protected power socket near the appliance from a qualified technician If the power cord is not long enough it must be replaced by a qualified...
Page 10: ...tion depending on the model Display screen default water temperature measured On off button Value setting buttons Steady Flashing Off On off On off Appliance powered up No electrical supply Heating li...
Page 11: ...ented Connect the regulation to the power supply and turn it on Adjust the temperature setpoint After the start up steps for your exchanger Check that there are no leaks Check that the circulating pum...
Page 12: ...u keep this mode which is suitable for most installations If however your appliance is close to the boiler you may lower the speed to speed 1 or 2 see 3 4 2 Operation of the circulating pump on Heat L...
Page 13: ...Unscrew the connectors to drain the exchanger Tighten the connectors slightly again when the exchanger is empty Tip Restarting the circulating pump after a long shutdown period depending on the model...
Page 14: ...ase The appliance may have detected an operating fault see 5 2 I Error code display Check that the automatic filling valve is not stuck in open position this will keep supplying cold water into the po...
Page 15: ...ating pump is defective Check the power supply voltage Replace the circulating pump The circulating pump is supplied with electricity Check the power supply voltage The circulating pump is blocked Use...
Page 16: ...Power cable 2L E 10 16A 3G1 HL Regulation thermostat with digital display CD Flow switch B White F1 3 15 A T protection fuse Bl Blue GN Black duct M Brown L1 On off LED N Black L2 REG LED flashing whe...