Page 9
Page 8
eXO
®
| Installation Manual
Section 4. Install Controller
The controller should be located at or near the
equipment pad, at least 3.5 metres or more away
from the inside wall of the pool/spa, 1.5 metres
off the ground, and within 2 meters of the cell. All
national, state, and local codes are applicable.
4.1 Mount the Bracket
1. Determine the controller location.
2. Use the enclosed bracket to mark the
mounting surface through the screw holes.
3. Drill surface with 7 mm bit.
4. Install the included wall anchors.
5. Hang bracket using the included screws.
6. Hang the controller on the wall bracket and
slide to the right to secure in place.
Figure 6. Controller Mount
4.2 Install Temperature Sensor
The temperature sensor must be installed
upstream from any heating equipment,
The sensor will need to be placed into
the plumbing system at any suitable position after
the filter pump and before any heating equipment.
1. Drill a Ø9 mm hole in the top of the pipe.
2. Ensure the o-ring is properly seated on the
sensor body.
3. Secure the sensor and o-ring with the screw
clamp provided. DO NOT OVERTIGHTEN.
Figure 7. Install Temperature Sensor
4.3 Electrical Connections
WARNING
FOR YOUR SAFETY:
This product must be
serviced by a professional pool/spa service
technician as described on the front cover of this
manual. The procedures in this manual must be
followed exactly. Failure to follow warning notices
and instructions may result in property damage,
serious injury, or death. Improper installation and/or
operation will void the warranty.
The controller must be permanently powered by
connection to a 30 mA residential circuit breaker.
The controller can be used to connect and control
multiple devices see Table 5 for a summary of functions.
WARNING
The controller is not to be considered as suitable for
use as service equipment. Therefore it is required to
have the appropriate means of disconnection, circuit
isolation, and/or branch circuit protection upstream
of the controller/device, in according with local wiring
rules.
4.3.1
Remove Lower Cover
1. Unplug power supply from mains.
2. Remove the external cover.
3. Remove the 2 screws from the lower housing.
4. Remove the lower housing by pulling down
Ø9 MM