background image

 WARNING

INSTALLATION AND 

OPERATION MANUAL

H0303600 Rev C

FOR YOUR SAFETY - 

This product must be installed and serviced by a contractor who is licensed and qualified in pool 

equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The 

maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that 

all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning 

notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in 

property damage, personal injury, or death. Improper installation and/or operation will void the warranty.  Improper 

installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, 

or death. 

ATTENTION INSTALLER - 

This manual contains important information about the installation, 

operation and safe use of this product. This information should be given to the owner/operator of this 

equipment.

Jandy Pro Series Levolor

®

 

Electronic Water Leveler 

Models K-1100, LX2, K-2300, and LEV110CK/2G

Sensor

Filling

Power

DO NOT OPEN

NO USER SERVICEABLE PARTS INSIDE

SENSOR

PWR

FILL

II

Electronic

Water Levelor

The next generation 

in automated controls.

SM

TM

Patented

High Voltage Compartment

No user service parts inside

Model No. K-2300

Sensor I

Sensor II

Filling 1

Filling II

Power

K-1100

LX2

K-2300

Sensor

Filling

Power

Model No. LEV110CK/2G

LEV110CK/2G

Summary of Contents for Jandy Pro Series Levolor

Page 1: ...ersonal injury or death Improper installation and or operation will void the warranty Improper installation and or operation can create unwanted electrical hazard which can cause serious injury proper...

Page 2: ...Page 2 ENGLISH Jandy Pro Series Levolor Electronic Water Leveler Models K 1100 LX2 K 2300 and LEV110CK 2G Installation and Operation Manual...

Page 3: ...grams 13 Section 4 Operation 16 4 1 K 1100 LEV110CK 2G and LX2 16 4 2 K 2300 17 4 3 Fill Safety Lockout Mode 17 4 4 Fill Time before Lockout 18 Section 5 Troubleshooting 19 5 1 Manual Valve Override 1...

Page 4: ...in pool spa installation and maintenance Improper installation or operation could cause serious injury property damage or death Improper installation or operation will void the warranty WARNING Before...

Page 5: ...ntrol Box The control boxes for K 1100 LX2 and LEV110CK 2G have three 3 LED displays Power Sensor and Filling The control box for the K 2300 has five 5 LED displays Power Sensor I Filling I Sensor II...

Page 6: ...iled views of the factory direct wiring for 220 VAC and the modified wiring for 110 VAC The section also contains a wiring diagram for the LX2 along with detailed views of the factory direct wiring fo...

Page 7: ...Operation BLK RED BLK Green Transformer 1 2 5 6 Ground Line Neutral BLK WHT BLK YEL 220 Volt Operation 110 Volt Operation Figure 5 K 1100 K 2300 and LEV110CK 2G Modified Wiring for 110 Volt Operation...

Page 8: ...ts Black Green Black Figure 6 LX2 Control Box See Figure 7 for factory direct wiring for 220 volt operation and Figure 8 for factory direct wiring for 110 volt operation Figure 7 LX2 Factory Direct Wi...

Page 9: ...ing Valve II Red Wires Filling Valve I Blue Wires Yellow Wire to Sensor Common Sensor Common Yellow Wire Sensor I Sensor II Black Wire Red Stripe Black Wire White Stripe Black Wire Yellow Stripe Black...

Page 10: ...Box NOTE When installing a Levolor on a spa less than 300 sq ft of surface area turn the flow control down to reduce the flow rate of the valve Models K 1100 K 2300 and LEV110CK 2G 1 Mount the control...

Page 11: ...d on the inlet side of the valve A 24 VAC solenoid valve will provide water from a supply line to the pool or spa You can install the supply line either before or after the filter at the equipment pad...

Page 12: ...slip sensor vertically in a static pipe Glue the sensor to the coupling See Figures 14 and 16 NOTE Screw the optional threaded sensor into a 1 threaded coupling NOTE When using the static pipe method...

Page 13: ...on Sensor in Skimmer Installation in Exisiting Pool Figure 16 Slip Sensor in Static Pipe Installation in New Pool 3 7 Installation Diagrams This section shows diagrams of skim half moon style and slip...

Page 14: ...onnection 1 PVC Cut to Length 2 Static Line Vented at Top by Drilling Hole in It Terminate Sensor at Minimum Operating Level Conduit to Sensor Control System at Control Box 9 Deck Lid 6 Figure 19 Deck...

Page 15: ...E Install Line Level or Run Uphill From Pool to Prevent Air Lock 1 Brass Y Strainer 110 220 VAC Figure 20 LX2 in Static Pipe Installation in New Pool Desired Water Level 1 Coupling Slip Sensor 1 PVC C...

Page 16: ...t takes longer to fill the pool than the time period allotted 20 40 or 60 minutes For more information see Section 4 3 Fill Safety Lockout Mode NOTE The time period allotted for the LEV110CK 2G to fil...

Page 17: ...Filling II light turns green indicating that Valve II is operational and filling The light turns off when the spa is filled and it turns red when Valve II goes into Safety Lockout Mode Note that the K...

Page 18: ...er S 1 See Figure 27 for location of LEV110CK 2G jumpers Model K 2300 The K 2300 factory set Fill time before Lockout is 20 minutes for both Filling I and Filling II To modify fill times cut jumpers a...

Page 19: ...connect Valve I from the blue wires in the control box and disconnect Valve II from the red wires in the control box 4 Restore power to the control box and observe the operation The control box is wor...

Page 20: ...h poly pro jacket 3 Valve is bad PCB board is bad Sensor is bad Does green fill light turn off Does green fill light turn off Is fill light on Disconnect blue valve wires from control box Does green f...

Page 21: ...nection between valve and controller is bad Less power Verify correct input voltage to unit Pull sensor out of water Does sensor light turn on YES YES YES YES YES YES YES NO NO NO NO NO NO NO Does uni...

Page 22: ...ded Style 2 Contact w 200 ft K 1100 K 2300 S2042G 9 Threaded Style 2 Contact w 50 ft 30 Sensor K 1100 K 2300 S2042A30 Skim Half Moon Style Skimmer Install 10 Half Moon Style 2 Contact w no wire K 1100...

Page 23: ...ft K 1100 LX2 K 2300 S2046K 11 Dual Style Sensor w 350 ft K 1100 LX2 K 2300 S2046M 11 Dual Style Sensor w 400 ft K 1100 LX2 K 2300 S2046O 11 Dual Style Sensor w 450 ft K 1100 LX2 K 2300 S2046Q 11 Dual...

Page 24: ...ystems com 2016 Zodiac Pool Systems Inc ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owners...

Reviews: