P a g e
|
22
Section 5. Operating Instructions
5.1
Control Panel
5.2
Turning Power Pack On/Off (Manually)
To turn the Zodiac AquaPure Ei Series APURE35C chlorine generating device on or off press the button.
NOTE
Because the power pack is wired to the pump’s power source, the power pack can only be turned on when the
pump is turned on.
5.3
Turning Power Pack On/Off (Using the Pump’s External Timer)
If the power pack is wired to the pump’s external timer and the power to the power pack is on, the power pack will
automatically turn on and off when the pump turns on and off (see Section 3.4). When the power pack is wired as such,
the only setting that must be set manually is the chlorine output level (see Section 5.4).
5.4
Setting the Chlorine Output Level
When setting the chlorine output level you must consider the size of the pool, the amount of use the pool will be receiving
and how hot the weather is. All these factors weigh greatly on the level of output needed. To adjust the output level,
follow these steps:
1.
Turn the power pack on by pressing the button.
2.
Press the button to reach the desired output level. The minimum setting is 20% (one amber light). The output can
be adjusted in increments of 20% up to 100%. If the OUTPUT button is pressed beyond 100%, the output level
setting will drop back to 20%.
5.5
Connection to an AquaLink
®
RS / PDA Control System
The Zodiac AquaPure Ei Series APURE35C chlorine generating device can be connected to an AquaLink RS or PDA
Control System (see Section 3.5 and 3.6). For detailed instructions for the AquaLink RS or PDA Control System, see the
respective manuals.
5.6
Polarity Reversal
The Zodiac AquaPure Ei Series APURE35C chlorine generating device is a reversible polarity cell which means that for
every five (5) hours of operation the cell will switch its polarity to help prevent any build up of calcium on the cell plates.
This is sometimes referred to as the automated cell cleaning feature. During the transition between changing its polarity
there is a five (5) minute wait time when the cell will not produce any chlorine. Once it has changed polarity it will
continue to make chlorine.
NOTE
‘CLEANING’ will be displayed on the screen during the five (5) minute ‘WAIT’ period. The output level
indicator will remain as set during the cleaning period
5.7
Backup Battery
WARNING
Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of electric
shock which can result in property damage, severe injury or death.