background image

正信光电科技股份有限公司

ZNSHINE PV-TECH CO.,LTD

Mounting Manual

INSTALLATION INSTRUCTION FOR SINGLE GLASS SOLAR MODULE

S

ingle glass solar modules are made of crystalline solar cells in series with high efficiency, high transmission

and low iron toughened glasses , anti-aging EVA and high flame-resistant back sheet to laminate, and anodized
aluminum alloy frame. Products have high efficiency, lifespan easy installation, high wind resistance etc.

Products are made according to international standard IEC61215-2016; IEC61730-2016 and have passed

authority test center’s examination. Our products can be used in home roof solar systems, PV stations,
communication stations, petrol, ocean, meteorological, traffic and solar building etc.

Information for installers
Installers must read and understand this manual before installation.
Please ensure that installation, operation and maintenance of your photovoltaic system is only carried

out by qualified persons able to carry out the technical procedures described in this manual, i.e. system planers,
installers and maintenance personnel, and is carried out in accordance with all safety precautions in this manual
and any and all applicable local codes. If you do not possess these qualifications, you may not carry out the work
described herein except for cleaning.

This manual and the instructions set forth herein are part of the product and should therefore be kept for

the entire useful life of the solar installation.

Information for operators
Keep these instructions safe for the entire useful life of the solar installation.
Please contact your plant supplier for information concerning the formal requirements for solar systems.

Please be sure to learn about directives and permit requirements from the responsible local authorities and
energy providers prior to installation of the solar plant.

We recommend that you insure your solar system against natural hazards (e.g. against lightning strikes).

Summary of Contents for ZXM6-60M

Page 1: ...your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and maintenance personnel and is ca...

Page 2: ...M6 66M ZXP6 66P Max series fuse rating A 15A Nominal Mass 22kg 21 5kg 19kg 19 5kg 20kg 21kg Package Size mm 1956 992 40 35 1956 992 40 35 1984 1002 40 35 1650x992x40 35 1666x1002x40 35 1808x992x40 35...

Page 3: ...NDITION Install the PV module in the following conditions Environment temperature 20 to 40 Operating temperature 40 to 80 Waterproof don t dip the modules into the water or continually explode under t...

Page 4: ...correct installation will lead to the loss of power The modules which are connected in series must be in the same angle otherwise it will lose power because of the difference in sunlight intensity Sol...

Page 5: ...diode to decrease the loss of energy the shadow will lead to the loss of output power 4 Grounding All module frames must be attached to an earth ground A qualified electrician must do the ground conn...

Page 6: ...er wire and Stainless steel M5 bolt 1 Copper wires with M5 cupped washer should be placed through the bolt 2 Put the cut washer through the bolt and the bolt must be put through the hole fixed in the...

Page 7: ...mum number of modules in parallel and in series for Vsys 1 25Voc 1 fuse rating Isc 1 6 Mounting A Fixation with screws The frame of each module has 8 9 14mm mounting holes used to secure the modules t...

Page 8: ...dware bolt split washer flat washer nut should be stainless steel M8 size Follow mounting guidelines recommended by the PV mounting supplier The mounting design must be certified by a registered profe...

Page 9: ...installation to allow water runoff This prevents frost damage Install the module in such a way that rainwater and snowmelt can run off freely to avoid standing water or pudding This resistance value c...

Page 10: ...modules are strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used must not come into contact with the front glass and...

Page 11: ...e This manual is just for reference Customer can select the corresponding installation manual based on the purchased module 8 Wiring The modules use thePV JX1201B type junction box This box on the bac...

Page 12: ...clean the modules rainfall will have a self cleaning effect In case of heavy soiling which will result in output reductions we recommend cleaning the modules using plenty of water from a hose without...

Page 13: ...modules or panels 12 Danger of death from arcing Modules generate direct current when light shines on them An arc may be produced when connections are separated We therefore recommend covering modules...

Page 14: ...ass 5 as mono panels doped with gallium non coated glass 7 as mono panels doped with boron coated glass 8 as poly panels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8...

Page 15: ...6 72 395 M Max Power Pm W 380 385 390 395 Max Power Voltage Vmp V 39 9 40 1 40 3 40 5 Max Power Current Imp A 9 53 9 61 9 68 9 76 Open Circuit Voltage Voc V 48 6 48 8 49 49 2 Short Circuit Current Isc...

Page 16: ...Dimensions mm Weight kg 1960 992 40 35 VDC Max System Voltage VDC 1500 A Max Series Fuse A 15 Electrical Performance STC Model Type ZXP6 72 350 P Max Power Pm W 350 Max Power Voltage Vmp V 38 3 Max P...

Reviews: