VPLC710 Motion Controller Hardware Manual V1.0
Chapter IV Installment Wiring
4.1.
Installment Environment
➢
Ambient temperature: The ambient temperature has a great influence on the life of
the controller, and the operating environment temperature of the controller is not
allowed to exceed the allowable temperature range (0°C to 55°C).
➢
Install the controller vertically on the surface of the flame-retardant object in the
installation cabinet, and there must be enough space around it for heat dissipation.
➢
Please install it in a place that is not easy to vibrate. Vibration should not be greater
than 4.9m/s^2. Take special care to stay away from equipment such as punch
presses.
➢
Avoid placing in direct sunlight, humidity, and water droplets.
➢
Avoid installing in places with corrosive, flammable and explosive gases in the air.
➢
Avoid installing in places with oil and dust, and the pollution level of the installation
place is PD2.
➢
This product is installed in the cabinet and needs to be installed in the final system.
The final system should provide corresponding fireproof enclosures, electrical
protection enclosures, and mechanical protection enclosures, etc., in compliance
with relevant IEC standards.
Item
Parameters
Work Temperature
-20
℃
-60
℃
Work relative Humidity
10%-95%RH non-condensing
Storage Temperature
-40
℃
~
70
℃
(not frozen)
Storage Humidity
Below 90%RH (no frost)
Vibration
Below 4.9m/s^2
Shock
Below 19.6m/s^2
Degree of Protection
IP20