EIO16084 Bus Expansion Module User Manual V1.5
Isolation mode
optoelectronic isolation
Note: the above parameters are standard values when the voltage of expansion
module power supply (E+24V port) is 24V.
3.3.2.
Digital Input Wiring
→
Wiring Note:
⚫
The wiring principle of digital inputs IN (0-15) is shown in the figure above. The
external signal source can be an optocoupler, a key switch or a sensor, etc., all can
be connected as long as the requirements on output of electric level can be achieved.
⚫
For the public end, please connect the "EGND" port on the power supply to the "COM"
terminal of the external input device. If the signal area power supply of the external
device and the power supply of the expansion module are in the same power supply
system, this connection also can be omitted.
3.4.
OUT Digital Output
→
Terminal Definition
Terminal
Name
Type
Function
EGND
/
External power ground
NC
/
Spare
OUT0
NPN leakage,
Output 0
Summary of Contents for EIO16084