ECI2410 Network Motion Control Card Hardware Manual Version1.4
17
Due to OD output, OFF of output will be affected obviously by external
load circuit. Therefore, it is not recommended to set too high output frequency,
it should be set below 400KHZ for high-speed output, and below 8Khz for
general output. If even higher speed is required, please contact with us to
adjust parameters or customize hardware.
2.2.6.3
Digital Output Terminal
PIN
Name
Description
1
OUT7
Output 7
2
OUT6
Output 6
3
OUT5
Output 5
4
OUT4
Output 4
5
OUT3
Output 3
6
OUT2
Output 2
7
OUT1
Output 1, high-speed output, PWM1
8
OUT0
Output 0, high-speed output, PWM0
9
EGND
External power ground (not connect to switch power)
10
EGND
External power ground (not connect to switch power)