If after the second round of calibration the user still decides that none
of the lines are accurate, the machine will show a warning screen and
advise to repeat the automatic calibration process or to perform the
manual calibration.
3D printing workflow
NOTE
If meeting calibration issues or autocalibration doesn’t work, please contact Technical Support
12.8 Manual calibration process
The manual calibration doesn’t require loading a filament (can be performed with an empty extruder).
Choose ‘MAINTENANCE’.
Choose ‘CALIBRATE’.
Choose ‘MANUAL CALIBRATION’.
Wait until the extruder is
placed in the right place.
Clear the nozzle and the
table from the unnecessary
material.
Take a small sheet of paper
and place it between the
nozzle and the worktable.
Press the ‘
GO TO CURRENT Z0
’
button.
Move Z-axis to make the nozzle barely
touching the bed and click “Set new Z0”
GO TO
CURRENT Z=0
Z
Z
SET NEW
Z=0
MOVE Z
BACK