Gas Supply
GAS SUPPLY
• This appliance shall only be installed by an authorized professional.
• If local codes permit, a flexible metal appliance connection with the new AGA or
CGA certified design, 3/4" (19 mm), is recommended for connecting this appliance
to the gas supply line. DO NOT bend or damage the flexible connector when moving
the appliance.
• This appliance must be used with the pressure regulator provided (see below). The
regulator must be properly installed in order to be accessible when the appliance is
installed in its final location. The pressure regulator must be set for the type of gas to
be used. The pressure regulator has 1/2" (13 mm) connection female pipe thread. The
appropriate fitting must be determined based on the size of your gas supply line, the
flexible metal connector, and the shut-off valve.
• The appliance must be isolated from the gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSI (3 kPa).
• All opening holes in the wall and floor, back and under the appliance shall be sealed
before installation of the appliance.
• A manual valve shall be installed in an accessible location in the gas line external to the
appliance for the purpose of turning on and shutting off the gas to the appliance.
Do not use aerosol sprays in the vicinity of this appliance
while it is hot.
WARNING
Pressure Regulator
BEFORE INSTALLATION