ALPINE SERIES RANGE HOODS
www.zlinekitchen.com
Installation and User Manual
Page 1: ...ALPINE SERIES RANGE HOODS www zlinekitchen com Installation and User Manual...
Page 2: ...en and bath of your dreams is never out of reach Through our unique designs and unparalleled quality we re dedicated to providing you an elevated experience in the heart of your home With an endless s...
Page 3: ...inually strive to improve our products we may change specifications and designs without prior notice Scan the QR code to view the most up to date version of the Installation Manual and User Manual WAR...
Page 4: ...llation 4 Installation 9 Operation 14 ISLAND MODELS 15 Before Installation 15 Installation 16 Operation 17 UNDERCABINET MODELS 18 Before Installation 18 Installation 19 Operation 23 MAINTENANCE AND CL...
Page 5: ...ts or accessories as sharp edges may lead to injury Use of gloves during installation is highly recommended The manufacturer will not be responsible for any damage to property or to persons caused by...
Page 6: ...ance with the National Electrical Code ANSI NPA70 latest edition and or local codes Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire or other hazard C...
Page 7: ...gh settings on the cooking range below only when necessary Never leave range top surface units underneath a range hood unattended at high settings Boilovers can cause smoking and greasy spillovers tha...
Page 8: ...ice technicians TOOLS AND PARTS NEEDED Aluminum tape Jigsaw or key saw Level Pencil Phillips head screwdriver Powered screwdriver drill Tape measure Stud finder OPTIONAL PARTS Cabinet jack Plywood Wid...
Page 9: ...with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A UL or CSA listed...
Page 10: ...d will lose its performance and efficiency Use metal ductwork only DO NOT use plastic ventilation DO NOT use 4 laundry type wall caps Fasten all connections with sheet metal screws Tape all joints wit...
Page 11: ...hood before executing any 90 turn No more than 3 elbows are allowed each 90 turn you make equates to 5 lost when accounting for the maximum 40 of ductwork Do not use any reducers on ducting smaller t...
Page 12: ...e Wall Cap Vertical roof venting Roof cap WARNING IMPORTANT NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the...
Page 13: ...od unit STEP 2 MARKING ON THE WALL DUCTING PIPE UPPER CHIMNEY BRACKET CHIMNEY WIDTH MOUNTING SCREWS CENTER LINE CEILING PLYWOOD 1 Center line is the center of cooktop or stove 2 Chimney width is the w...
Page 14: ...cket on the wall Loosely fasten two Type B screws onto anchors DO NOT fasten screws all the way Hang the range hood on the Type B screws and hand tighten them Leave approximately 1 8 of gap from the w...
Page 15: ...abinet jack if desired 2 Level the hood body by using a horizontal level 3 Use a screwdriver to tighten the 2 mounting screws 4 Connect the exhaust on the hood to the ductwork above 5 Use aluminum tap...
Page 16: ...hood to the stud 4 Refer to Operation on page 14 to familiarize yourself with the button controls Try a few test runs to ensure the hood is running properly STEP 6A FOR GLASS CANOPY MODELS ONLY INSTA...
Page 17: ...on both sides 6 Remove inner chimney protective film STEP 8 BAFFLE FILTERS INSTALL AND REMOVAL WARNING FOR MODELS THAT HAVE MORE THAN 2 BAFFLE FILTERS ALWAYS INSTALL THE MIDDLE FILTER LAST LIKEWISE R...
Page 18: ...and press the power off delay button one time It will enter timer mode and the power off delay digital timer will begin countdown Press again and the blower will shut down Never put your hand into are...
Page 19: ...ch is intended for qualified installers and certified service technicians TOOLS AND PARTS NEEDED Aluminum tape Jigsaw or key saw Level Pencil Phillips head screwdriver Powered screwdriver drill Tape m...
Page 20: ...Slide chimney pieces over the angle iron on the hood Pull the electrical plug to the top of the chimney sections 7 Lift the hood to attach the angle iron to the ceiling bracket Use screws provided to...
Page 21: ...delay button one time It will enter timer mode and the power off delay digital timer will begin countdown Press again and the blower will shut down Never put your hand into area housing the fan while...
Page 22: ...screwdriver Stud finder Tape measure OPTIONAL PARTS Cabinet jack Plywood Wide enough to cover the cooking surface below the hood PARTS SUPPLIED Baffle filters Body and main range hood unit Installati...
Page 23: ...2nd choice This is the most efficient way and highly recommended Ducting goes vertically above the range hood through the house s roof SIDE WALL VENTING 3rd choice Ducting goes through the kitchen cei...
Page 24: ...xhaust under the cabinet For easy installation cut about 1 4 larger diameter for both ducting and power cord plug STEP 5 ATTACH THE HOOD 8 Metal Duct Range Hood Ply wood Or Solid Flatform Cabinet Jack...
Page 25: ...at each corner of hood the body Top view A Use a stud finder to find the stud and use 1 8 drill bit to drill though the back of the hood Secure the hood by using provided screws though the back of the...
Page 26: ...llowing steps NOTE The middle filter has to be installed last and it should be taken out first when you want to remove other filters 1 Angle baffle filter toward back of hood 2 Lift the baffle filter...
Page 27: ...elay button one time It will enter timer mode and the power off delay digital timer will begin countdown Press again and the blower will shut down Never put your hand into area housing the fan while t...
Page 28: ...rn about 90 degrees Horizontal wall venting Vertical roof venting Roof cap Side wall cap CENTER LINE CEILING PLYWOOD 4 Pull the bulb straight out of the socket 36 BASE Horizontal wall venting Vertical...
Page 29: ...If hood looks splotchy use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution on or into the control panel Do NOT leave cleaner on too long as this may cause da...
Page 30: ...with insufficient duct size and loosely secured Check if duct is clogged or if damper unit is not opening properly A tight mesh on a side wall cap unit might also cause restriction to the airflow The...
Page 31: ...esults of faulty workmanship or material use Some of these troubleshooting items are specific to certain types of ZLINE range hoods Your product may not have some of the features described here If a p...
Page 32: ...on or defects in materials are not covered under the terms of this warranty TERMS ZLINE warranties apply only to the original purchaser of a ZLINE product installed for normal residential use This is...
Page 33: ...mber has been removed altered or cannot be readily determined for any reason Further ZLINE is not responsible for damage resulting from but not limited to shipment delivery or improper installation ne...
Page 34: ...4 for help Failure to report a damaged appliance prior to installation or operation may void the warranty ZLINE does not perform service repairs on its range hood products ZLINE disclaims responsibili...
Page 35: ...4 or visit www zlinekitchen com contact to utilize our online Customer Experience Portal Scan the QR code to view the most up to date version of ZLINE s range hood Installation and User Manuals Need t...
Page 36: ...1 614 777 5004 www zlinekitchen com contact zlinekitchen com 2 1 0...