CANDTU-400ER
CAN Bus Message Recording and Wireless Data Transmission Equipment User Manual
©2021 Guangzhou ZLG Electronics Technology Co.,Ltd.
23
User Manual
Figure 4.14:
1) Timing interval
In the preset time interval, record the last message of a specific ID. If no data is
received, it will be filled or not recorded according to the settings.
2) Add frame recording conditions
Click the "Add" button to display the timing record ID configuration dialog box. Add
record conditions in this dialog box, as shown in Figure 4.15.
3) When there is no data in the timing interval
If no data is received for the specified ID within the preset period, it will be processed
according to the following options
Not recorded
Record with last received data
Fill in the records with custom data
5.
Not recorded
In this mode, data will not be recorded during normal device operation .
4.3.4 Flipping the Recorder
After the flip recorder is enabled, if the message received by the ID in the rule is the
same as the message recorded last time, the message will not be recorded. When the
device receives the ID packet in the rule, it judges the data content of the packet. If the
data segment is the same as the last recorded message data segment, the device does
not record this frame of data until the received message data segment is different.