Table 2.4 Protection level-electrical fast transient pulse group immunity test (IEC61000-4-4)
Interface
Conditions
Test Level
Test
Voltage
(kV)
Test
Result
Remarks
Power supply
Level 3
2
Class A
Capacitive
coupling
CAN bus
Level 3
1
Class B
Capacitive
coupling
Table 2.5 Protection level-surge (impact) test (IEC61000-4-5)
Interface
Conditions
Test Level
Test
Voltage
(kV)
Test
Result
Remarks
Power supply
Level 3
1
Class A
Line-line
Level 3
2
Class A
Line-ground
CAN bus
Level 3
1
Class B
Line-line
Level 3
1
Class B
Line-ground
Note: For details, see the attachment Electromagnetic Compatibility Test Report.pdf.
2.4 Mechanical Dimensions
Figure 2.1 shows the mechanical dimensions (unit: mm).
Figure 2.1 Mechanical dimensions
Note: For more detailed mechanical dimension drawings, contact our sales or technical support
personnel.