background image

ZK-D1065TDM

 

                

User Manual

 

P a g e

 | 20 

Copyright©2021 ZKTECO CO., LTD.    All rights reserved.

 

6

 

Detection Zones 

The ZK-D1065TDM detectors can detect a wide range of threat 
objects/weapons composed of magnetic, non-magnetic metals and alloys. 

Chassis panel:

 The screen shows the number of people passing the detector 

and the number of alarms. 

Alarm zones: 

 

6 zones:

 The zones are classified as 1 to 6 from bottom to top. 

There are six unique sets of precise positioning LED’s evenly distributed on 

Summary of Contents for ZK-D1065TDM

Page 1: ...the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For further details please visit our Company s website www zkteco com User Manual Walk Through Metal Detector ZK D1065TDM Date March 2021 Doc Version 1 0 English ...

Page 2: ...he property of ZKTeco The contents hereof should not be used or shared by the receiver with any third party without express written permission of ZKTeco The contents of this manual must be read as a whole before starting the operation and maintenance of the supplied equipment If any of the content s of the manual seems unclear or incomplete please contact ZKTeco before starting the operation and m...

Page 3: ... information is assumed by the user ZKTeco in no event shall be liable to the user or any third party for any incidental consequential indirect special or exemplary damages including without limitation loss of business loss of profits business interruption loss of business information or any pecuniary loss arising out of in connection with or relating to the use of the information contained in or ...

Page 4: ...ration of the machine and equipment in conditions different from the prescribed conditions of the manual The product will be updated from time to time without prior notice The latest operation procedures and relevant documents are available on http www zkteco com If there is any issue related to the product please contact us ZKTeco Headquarters Address ZKTeco Industrial Park No 32 Industrial Road ...

Page 5: ...h and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhancement of the development and plenty of market applications the team has gradually constructed an identity authentication ecosystem and smart security ecosystem which are based on bi...

Page 6: ...ption Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description This implies about the notice or pays attention to in the manual The general information which helps in perf...

Page 7: ...AUTIONS 12 INSTRUCTIONS TO PEDESTRIANS 13 INSTALLATION SITE 14 3 3 1 STATIONARY METALLIC ITEMS 14 3 3 2 PORTABLE METALLIC ITEMS 14 3 3 3 FLOOR VIBRATION 14 3 3 4 ELECTROMAGNETIC RADIATION AND INTERFERENCE 14 3 3 5 PARALLEL INSTALLATION 15 INSTALLATION STEPS 15 4 PERFORMANCE AND TECHNICAL FEATURES 17 5 CONTROL PANEL 18 6 DETECTION ZONES 20 ADJUSTMENT OF DETECTION ZONE S SENSITIVITY 21 7 OPERATIONAL...

Page 8: ...021 ZKTECO CO LTD All rights reserved BUZZER SETTINGS 23 ALARM TIME 24 DATE AND TIME 24 SENSITIVITY RANGE 25 APPLICATION AREA 25 DATA STORAGE 26 LOGIN PASSWORD 26 RESTORE 27 DEFAULT PARAMETERS 27 TROUBLESHOOTING 28 PACKING LIST 29 WARRANTY CARD 30 ...

Page 9: ...ature measurement at the forehead and wrist of passengers It integrates the box of TDM95E When people pass through the device put the hand or wrist 3 5cm away from the TMD95E can measure the temperature If the temperature detected is over 37 3 C ZK D1065TDM will raise an alarm to inform the guards Then the security personnel can find the fever person by the voice of beep Appearance ...

Page 10: ...ZK D1065TDM User Manual P a g e 9 Copyright 2021 ZKTECO CO LTD All rights reserved Components 1 Beam 2 LED Alarm Zones 3 Built in Probe 4 Infrared Sensors 5 TDM95E 6 Power line Interface 2 3 4 5 6 1 ...

Page 11: ...ZK D1065TDM User Manual P a g e 10 Copyright 2021 ZKTECO CO LTD All rights reserved 2 Product Specifications Dimensions ...

Page 12: ...king 41KG Dimension H W L 2213 831 471 mm Dimension with Packing H W L 2280 282 560 mm Temperature Detection Distance 3 5cm Temperature Sensor Type IR temperature sensor Temperature Measurement Range 32 0 C 42 9 C 89 6 F 109 22 F Temperature Measurement Deviation 0 3 C 0 54 F Temperature Measurement Point Forehead or wrist Digital Display Tube 4 Operating Temperature 15 C 35 C 59 F 95 F Operating ...

Page 13: ...ng a security check to avoid false alarm Install the detector away from radio frequency devices to avoid interference Make sure that there is no large metal object or strong magnetic field around the detector for at least 2 meters Do not hit the detector hardly as it may cause false alarms Do not disassemble the unit without the guidance of a professional technician Each device has a warranty card...

Page 14: ...e passes through that means there is are some metal object s hidden in the body The security guard can use a hand held metal detector to accurately detect the hidden position according to the alarm zones When a person places his her wrist or palm in front of the device within the specified measuring distance the temperature measurement program is triggered and the output is displayed When the temp...

Page 15: ...on The installation floor must be flat and fixed to avoid false alarm from the movement of the people walking through the detector 3 3 4 Electromagnetic Radiation and Interference Since the detector uses Bilateral receiver technology the detector must be installed away at a distance of at least 1 meter from the sources of electromagnetic radiation or electromagnetic interference The parameters tha...

Page 16: ...rate at a different frequency to avoid interference The distance varies according to the actual working environment it is not recommended to mount three detectors in parallel the frequency can be adjusted according to the environment Installation Steps Make sure that the device is installed as per the following installation instructions If you want to open the chassis you should contact the agent ...

Page 17: ...o the control unit with bolts and nuts and tighten the screws There are a cable from the control unit to the holder Fiirst connect to the TDM95E via USB cable And put the TDM95E to the holder Insert the probe lines of the left and right door panels to the corresponding sockets on the mainboard Then lift the Walk through metal detector vertically and place it in the required area Finally plug in th...

Page 18: ...chnology Digital signal processing and filtering system in the detector has excellent anti interference ability Count Statistics The detector displays the number of pedestrians passed and Alarm count accurately Harmless The detector is harmless to heart pacemakers pregnant women magnetic floppy disks recording tapes etc Waterproof Foot Cover The waterproof foot cover not only can fix the device fi...

Page 19: ...nel are given below LCD Displays the Pass count Alarm count Password settings and other information ESC Press to discard the settings and exit the menu Adjustment decrement key to decrease the parameter values Adjustment increment key to increase the parameter values OK Opens the Menu interface saves the settings and exits the menu ...

Page 20: ... D1065TDM User Manual P a g e 19 Copyright 2021 ZKTECO CO LTD All rights reserved Temperature LED Color Signal Sound 32 0 C to 37 3 C Green 1 Short Tone 37 4 C to 43 C Red Long tone Red LED on for 15 sec ...

Page 21: ... a wide range of threat objects weapons composed of magnetic non magnetic metals and alloys Chassis panel The screen shows the number of people passing the detector and the number of alarms Alarm zones 6 zones The zones are classified as 1 to 6 from bottom to top There are six unique sets of precise positioning LED s evenly distributed on ...

Page 22: ... perform the following steps 1 Power on the detector and check whether it is not shaking after one minute 2 The device should not alarm when the testing person did not carry any metal items while walking through the detector 2 You can exclude the small portable metal objects such as rings key belt buckle shoes and so on by following the steps given below 1 Choose a small metal as a sample Increase...

Page 23: ...ions Press the OK button on the Control panel to open the main menu Sensitivity Adjustment On the main menu select Sensitivity and press OK to set the sensitivity level of each detection zone Press and to select the detection zone and then press OK to confirm Then press and to change the sensitivity MENU Sensitivity Channel Buzzer Alarm Time Date Time Sens Range Application Storage Relay Password ...

Page 24: ...Zone 5 100 Zone 4 100 Zone 3 100 Zone 2 100 Zone 1 100 Operating Frequency In the main menu select Channel and then press OK The channel range is from 1 to 40 The default value is 14 Press and to select the Channel and then press OK to save the settings Channel 01 40 Buzzer Settings In the main menu select Buzzer and then press OK to confirm Press and to select whether to turn on or off the buzzer...

Page 25: ...1 second Press and to select the alarm time as per your requirements and press OK to save the settings Alarm Time 0 5s 1 0s 1 5s 2 0s 10 0s Date and Time In the main menu select Date Time and then press OK to open the time and date setting interface Press and to adjust the time Press OK after setting the time Then press ESC and then switch to date Set the date and then press OK to save the changes...

Page 26: ...vity levels Press and to select the sensitivity settings for all the zones Press OK to save the settings Sens Range High Medium Low Application Area In the main menu select Application and then press OK to confirm Press and to adjust the real time application area Press OK after setting the application area Application Airport Customs Port Prison Detention Conference Train Station Motor Station Po...

Page 27: ...ge Save Don t Save Clear Pass Clear Pedestrian Count Clear Alarm Clear Alarm Count Login Password In the main menu select Password to configure the Password Press and to set the password and press ESC to clear the entered value Press OK to save the settings Password New Password Note 1 When the Network Address is 255 255 255 255 it is connected automatically You need to connect a network cable to ...

Page 28: ...loss and factory reset parameters will restore the default mask to 255 255 255 0 Restore In the main menu select Restore to restore the factory settings Select Yes and press OK to restore the original factory settings Select Cancel or press ESC to cancel the operation Restore Cancel Yes Default Parameters Parameter Default Value Sensitivity ZK D1065TDM 86 Channel 14 Buzzer ON Alarm Time 1 0 s Appl...

Page 29: ...sensor What to do if the detector gives a false alarm 1 If the device gives false alarms frequently after installation perform the following steps Firstly check the installation environment Make sure there are no movable or stationary large metal objects around 1 5 meters from the detector If there is any metal object try to place the device away from the large metal objects Make sure that the ins...

Page 30: ...t The package consists of the following items No Component Quantity 1 Power Adapter 1 set 2 Power Cable 1 set 3 Hexagon Socket Set Screw 8 pcs 4 Inner Hexagon 1 pc 5 User Manual 1 6 Front Beam 1 pc 7 Rear Beam 1 pc 8 Panel 2 sets 11 Infrared remote control ZK D1065TDM Optional 1 pc 12 TDM95E 1 pc ...

Page 31: ...ealer 3 This card will be regarded as invalid if the details are not filled in three guarantees column and the acknowledgment of the receipt Please confirm whether the data filled in the three guarantees column and acknowledgment of receipt is correct or not when purchasing it and then hand it over to the dealer 4 This card will not be issued again if it is lost Model Number ID Date of Acquisition...

Page 32: ...ZK D1065TDM User Manual P a g e 31 Copyright 2021 ZKTECO CO LTD All rights reserved Date of Maintenance Record of Maintenance Technician ...

Page 33: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved ...

Reviews: