The master and slave of a SBTL3000 swing barrier turnstile may either form a channel, or form two
channels with a SBTL3200 swing barrier turnstile,as shown in figure 2-2B;
Figure2-2B
SBTL3000
Single
channel
and
dual
channel
2.3
Cables
Installation
and
Fixation
For
the
outlets
of
the
concealed
cables,
please
refer
to
the
drawing
showing
the
mounting
holes.The
input
voltage
for
this
swing
barrier
turnstile
is
AC100-120V/200-240V
and
its
master
and
slave
are
connected
by
a
6-core
cable.
When
installing
this
swing
barrier
turnstile,
the
user
only
needs
to
connect
it
to
the
corresponding
ports.Note
that
the
PVC
conduits
are
buried
100mm
below
the
ground,
with
the
height
of
the
exposed
part
not
exceeding
100mm.
In
addition,
the
conduit
outlet
is
bent
back
to
prevent
ingress
of
water
into
the
conduit.
SBTL2000
installation
holes
and
cabling
positions
as
shown
in
Figure
2-3A.
SBTL3000
installation
holes
and
cabling
positions
as
shown
v
in
Figure
2-3B
.
Figure
2-3A