In default settings, new users are allocated into the first group with the default group time zone,
where the access combo is "1" and is set in unlock state by default.
Access Control Options
11.1
Tap
Access Control Options
on the
Access Control
interface to set the parameters of the control lock of
the terminal and related equipment.
Access Control Terminal:
Function Description
of Access Control Terminal:
Function Name
Description
Gate Control Mode
It toggles between
ON
or
OFF
switch to get into gate control mode or not.
When set to
ON
, the interface removes the Door lock relay, Door sensor relay,
and Door sensor type options.
Door Lock Delay (s)
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1 to 99 seconds; 0 seconds represents disabling the function.
Door Sensor Delay (s)
If the door is not locked and is left open for a certain duration (Door Sensor Delay),
an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.