Product Appearance 

2.2

Front View: 

 

 

LED  Indicator: 

The LED indicator is used to display device operation 

results and exceptional statuses which are defined as follows: 

Common Rules:

 If an operation succeeds, the green indicator is solid 

on for one second; otherwise, the red indicator is solid  on for one 
second. 

Enrollment State:

 The green LED blinks three times every other three 

seconds. 

Single  User  Deletion:

  The red LED blinks three times every other 

three seconds. 

Verification  State:

  The green LED blinks once every other two 

seconds. 

LED Indicator 

Card Swiping Area 

Fingerprint Sensor 

Summary of Contents for ma 300

Page 1: ...ead the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For furt...

Page 2: ...roperty of ZKTeco The contents hereof should not be used or shared by the receiver with any third party without express written permission of ZKTeco The contents of this manual must be read as a whole...

Page 3: ...ssumed by the user ZKTeco in no event shall be liable to the user or any third party for any incidental consequential indirect special or exemplary damages including without limitation loss of busines...

Page 4: ...hine and equipment in conditions different from the prescribed conditions of the manual The product will be updated from time to time without prior notice The latest operation procedures and relevant...

Page 5: ...ndent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication f...

Page 6: ...precautions The notations contained in this manual include indicates important information including precautions which must be read carefully to achieve the optimal equipment performance indicates th...

Page 7: ...NS 10 2 1 PRODUCT APPEARANCE 11 2 2 VERIFICATION STATE 13 2 3 MANAGEMENT CARD 14 2 4 OPERATION TIMEOUT 15 2 5 3 DEVICE OPERATIONS 16 MANAGEMENT CARD 16 3 1 3 1 1 Enroll Management Card 16 3 1 2 Enroll...

Page 8: ...Operation Log 37 4 3 7 Wiegand Setup 38 DEVICE MANAGEMENT 41 4 4 4 4 1 Update and Reset 41 4 4 2 Load Certificate 42 5 CONNECT TO ZKBIOACCESS IVS SOFTWARE 43 SET THE COMMUNICATION ADDRESS 43 5 1 ADD D...

Page 9: ...ng fingers Avoid using your thumb or pinky on the fingerprint reader because they are difficult to press accurately Note Please use the correct method when pressing your fingers onto the fingerprint r...

Page 10: ...duce the best results the device should be used at temperatures ranging from 0 C to 50 C It is advised to adopt a sunshade and heat dissipation facilities if the device will be exposed to the outdoors...

Page 11: ...rations You can use a management card to conduct tasks like offline enrollment user enrollment and U disk management Without the need of a screen and a keyboard the voice prompts will guide you throug...

Page 12: ...ed as follows Common Rules If an operation succeeds the green indicator is solid on for one second otherwise the red indicator is solid on for one second Enrollment State The green LED blinks three ti...

Page 13: ...U disk Reset Button Used to restart the device Speaker Used to play the BEEP sound and voice prompts If a user passes the verification the speaker beeps once and prompts Thank you If the user fails to...

Page 14: ...2 3 Verification state If you have enrolled or successfully enrolled in a management card or if any operation timeouts the device enters the verification state once it is turned on All users can verif...

Page 15: ...ecially allocated for a super administrator Each device must enroll a management card If no management card is enrolled you cannot perform any operation and the system will generate a voice prompt Ple...

Page 16: ...device For details see 4 3 4 The fingerprints of the user who bears a management card can only be enrolled through software For details see 5 3 Tip Users who bear management card can only verify thei...

Page 17: ...t state Then proceed with step 3 otherwise skip to step 5 3 After the system generates the voice prompt Please register the management card you can swipe your card across the sensor area Tip The devic...

Page 18: ...Each user is allowed to enroll 10 fingerprints and one card at most To enroll a user proceed as follows 1 In the verification state the system goes into the ordinary user enrollment state after you sw...

Page 19: ...nerates the voice prompt Register Please press your finger the system enters the specified fingerprint enrollment state Press the same finger over the sensor three times following the voice prompts c...

Page 20: ...waiting for you to press your finger or swipe your card b After generating the voice prompt Register Please press your finger or punch your card the system enters the specified user information enroll...

Page 21: ...lment state Your enrolled fingerprints will overwrite all previous fingerprints b Press the same finger over the sensor three times following the voice prompts by adopting the proper fingerprint place...

Page 22: ...r previous fingerprints c If the card enrollment succeeds the system generates the voice prompt Registration is successful Register Please press your finger and enters the fingerprint enrollment state...

Page 23: ...Are both 10 fingers and card enrolled Return to the verification state Yes No Yes Yes Yes Yes No No No No No User number Registration is successful The system returns to the verification state The num...

Page 24: ...or swipe the card over the card reader 1 Press your finger onto the sensor to delete a user Press one of your enrolled fingers properly onto the sensor If the verification succeeds the system will ge...

Page 25: ...rs Please press your finger or punch your card and automatically return to the deletion state If the verification fails the system will generate the voice prompt Please punch your card again 3 If you...

Page 26: ...card 5 times in a row Card verification Fingerprint verification Is card verification successful Is fingerprint verification successful Delete user Return to the verification state after the managemen...

Page 27: ...ion 1 Fingerprint Verification Press your finger on the fingerprint sensor in a proper way If the verification succeeds the system generates the voice prompt Thank you and concurrently triggers an unl...

Page 28: ...ation Fingerprint verification Card verification successful Fingerprint verification successful Unlock and delay Lock Door status detection Return to verification state Yes No Yes No Yes No Tip The ad...

Page 29: ...rmware through a U disk U disk Operations If you connect a U disk to the device the system will automatically prompt you of the operations in sequence 1 After connecting a U disk to the device you can...

Page 30: ...and held down with a rear cover When the device is dismantled the tamper switch will be lifted and then it will send an alarm signal to trigger an alarm Clear Alarm The user can clear the alarm by pu...

Page 31: ...served device will restart automatically and prompts Please register the management card Tips 1 The user data will be cleared including the administrator and ordinary users 2 The IP address of the dev...

Page 32: ...a browser and input the link https IP address the device to enter the login interface e g the default IP address of the device is 192 168 1 201 and the webserver link is https 192 168 1 201 Note The I...

Page 33: ...Confirm your password Then click OK as shown below Note 1 The password must be changed when logging in for the first time 2 The new password must be 8 digits and it must consist of symbols and any tw...

Page 34: ...evice 4 2 4 2 1 Device Status Click Device Status to view the Device name Serial number MAC address etc of the current device 4 2 2 Change Password Click Change Password to modify the user password En...

Page 35: ...IP addresses for clients via server If DHCP is enabled IP addresses cannot be set manually IP Address The default value is192 168 1 201 it can be modified according to the available network parameter...

Page 36: ...ription is as follows Enable URL When the software is in HTTPS mode the setting should be enabled you need to type the complete server address and communication port as shown in the figure above Cloud...

Page 37: ...value and click OK The fields description is as follows Volume Adjust the volume of the device which can be set between 0 to100 4 3 4 Data Management Click Data Management to delete the relevant data...

Page 38: ...Time to set the device date and time The fields description is as follows Auto Automatically synchronizes the PC time Manual Need to manually input the date and time Note The date format is required t...

Page 39: ...egand Format Its value can be 26 bits 34 bits 36 bits 37 bits and 50 bits Wiegand Bits The number of bits of the Wiegand data Pulse Width us The value of the pulse width sent by Wiegand is 100 microse...

Page 40: ...en parity bit of the 2nd to 13th bits while the 26th bit is the odd parity bit of the 14th to 25th bits The 2nd to 9th bits is the site codes while the 10th to 25th bits are the card numbers Wiegand34...

Page 41: ...5th bits The 2nd to 19th bits is the device codes and the 20th to 35th bits are the card numbers Wiegand37 OMMMMSSSSSSSSSSSSCCCCCCCCCCCCCCCCCCCE It consists of 37 bits of binary code The 1st bit is th...

Page 42: ...to 49th bits are the card numbers C denotes the card number E denotes the even parity bit O denotes the odd parity bit F denotes the facility code M denotes the manufacturer code P denotes the parity...

Page 43: ...ord of the webserver and IP address of the device will be restored to default 2 The user data won t be cleared Reboot Restart the device 4 4 2 Load Certificate Click Load Certificate to upload the dev...

Page 44: ...ote The IP address should be able to communicate with the ZKBioAccess IVS server 2 Click Cloud Settings to set the Server address and Server port Enable URL When the software is in HTTPS mode the sett...

Page 45: ...e Software 5 2 You can add a device by searching The process is as follows 1 Click Access Device Search to open the Search interface 2 Click Search and it will prompt Searching 3 After searching the l...

Page 46: ...user 3 Click Access Device check the device to be operated and click Control Synchronize All Data to Devices to synchronize all the data to the device How to enroll the fingerprints of the user who b...

Page 47: ...first 3 After the registration is successful click Access Device check the device to be operated and click Control Synchronize All Data to Devices to synchronize all the data to the device Note 1 The...

Page 48: ...pply 12V 3A Function Access control device door sensor alarm lock exit button One Wiegand input and one Wiegand output User Quantity 10 000 fingerprint and ID card Record Capacity 100 000 pieces of re...

Page 49: ...carefully and understand all the rules and provisions of this Privacy Policy If you do not agree to the relevant agreement or any of its terms you must stop using our products and services I Collecte...

Page 50: ...Security and Management 1 When you use our products for the first time you shall set the Administrator privilege before performing specific operations Otherwise you will be frequently reminded to set...

Page 51: ...e of the potential security risks 5 All the data collected by our products is encrypted using the AES 256 algorithm All the data uploaded by the Administrator to our products are automatically encrypt...

Page 52: ...guardians explicit consent and such use or disclosure is for the purpose of protecting minors Upon noticing that we have collected personal information of minors without prior consent from verifiable...

Page 53: ...eco friendly operational period specified for this product does not include batteries or other components that are easily worn down and must be periodically replaced The battery s eco friendly operati...

Page 54: ...06 Indicates that the total amount of toxic content in all the homogeneous materials exceeds the limit as specified in SJ T 11363 2006 Note 80 of this product s components are manufactured using non t...

Page 55: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2023 ZKTECO CO LTD All Rights Reserved...

Reviews: