G4L
User Manual
P a g e
| 72
Copyright©2020 ZKTECO CO., LTD. All rights reserved.
11.6
Duress Options Settings
Once a user activates the duress verification function with a specific authentication method(s), and when
he/she is under coercion and authenticates using duress verification, the device will unlock the door as
usual, but at the same time, a signal will be sent to trigger the alarm.
•
On the
Access Control
interface, tap
Duress Options
to configure the duress settings.
Function Description
Function Name
Description
Alarm on 1:1
Verification
When a user uses any fingerprint to perform the 1:1 verification, an alarm
signal will be generated only when the 1:1 verification is successful,
otherwise there will be no alarm signal.
Alarm on 1:N
Identification
When a user uses any fingerprint to perform 1:N verification, an alarm signal
will be generated only when the 1:N identification is successful, otherwise
there will be no alarm signal.
Alarm on Password
When a user uses the password verification method, an alarm signal will be
generated only when the password verification is successful, otherwise there
will be no alarm signal.
Alarm Delay (s)
Alarm signal will not be transmitted until the alarm delay time is elapsed.
The value ranges from 1 to 999 seconds.