Normal Open: It means the door is always left opened when electric power is
on.
Normal Closed: It means the door is always left closed when electric power is on.
Door sensor alarm
delay
When the state of the door sensor is inconsistent with that of the door sensor
type, an alarm will be triggered after a specific time period, i.e. the Door Alarm
Delay. The valid value ranges from 1 to 999 seconds. 0 indicates an immediate
alarm.
Error alarm
If enabled, when the number of failed verifications reaches 3 times, an alarm will
be triggered.
Normally close
period
Time period is scheduled for the “Normal Close” mode so that no one can gain
access during this period.
Normally Open
Time Zone
Scheduled time period for “Normal Open” mode, so that the door is always left
open during this period.
Normally open or
close is enabled
during holiday
To set if Normal Close Period or Normal Open Period settings are valid during
the holiday time period. Choose ON to enable the functions during a holiday.
Auxiliary Input
Configuration
Sets the door unlock time period and auxiliary output type of the auxiliary
terminal device. Auxiliary output types include None, Trigger door open, Trigger
Alarm, Trigger door open and Alarm.
Alarm
The default is Off.
Local Alarm
Transmits a sound alarm or disassembly alarm from the local. When the door is
closed or the verification is successful, the system will cancel the alarm from the
local.
External Alarm
The default is Off.
Reset Access
Settings
The restored access control parameters include door lock delay, door sensor
delay, door sensor mode, normally close period, normally open time zone,
auxiliary input configuration and alarm. However, the access control data in
Data Mgt. is excluded.
5.2
Time Rules Setting
Time Rule
is the minimum time unit of access control settings and a maximum of 50
Time Rules
can be set for the system. Each
Time Rule
consists of 7 time periods (a week) and 3 holiday time
schedules, and each time section is valid for 24 hours.
The user may set a maximum of 3 time periods for every time rule. The relationship among these
time periods is "or". When the verification time falls in any one of these time periods, the
verification is valid. The time period format is HH:MM-HH:MM in the 24-hour system with precision
to minute.
Summary of Contents for G4[QR]
Page 31: ...G4 QR User Manual P a g e 31 Copyright 2021 ZKTECO CO LTD All rights reserved...
Page 59: ...G4 QR User Manual P a g e 59 Copyright 2021 ZKTECO CO LTD All rights reserved...
Page 104: ...G4 QR User Manual P a g e 104 Copyright 2021 ZKTECO CO LTD All rights reserved...
Page 111: ...G4 QR User Manual P a g e 111 Copyright 2021 ZKTECO CO LTD All rights reserved...
Page 122: ...www zkteco eu Copyright 2021 ZKTECO CO LTD All Rights Reserved...