Speaker Test

To automatically test whether the audio files stored in

the device are complete and the voice quality is

good.

4.7

System Password

The System Password feature is used to improve the security of data.

Click

System Password

on the main menu.

Enter a password and re-enter it. Click

OK

. If the two entered passwords are

different, the prompt "Password not match” will appear. The default password
is 0, which can be changed, the password may contain1 to 6 digits.

4.8

Record Query

When a person passes through the detector, the details will be saved in the
device. This function allows the user to search for a detection record.

Click

Record Query

on the main menu.

Summary of Contents for FMD Pro 2.0

Page 1: ...our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative pu...

Page 2: ...the receiver with any third party without express written permission of ZKTeco The contents of this manual must be read as a whole before starting the operation and maintenance of the supplied equipm...

Page 3: ...or any incidental consequential indirect special or exemplary damages including without limitation loss of business loss of profits business interruption loss of business information or any pecuniary...

Page 4: ...ne and equipment in conditions different from the prescribed conditions of the manual The product will be updated from time to time without prior notice The latest operation procedures and relevant do...

Page 5: ...d for independent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity auth...

Page 6: ...0 1 6 DETECTION DISTANCE 11 1 7 COMPONENTS 12 2 INSTALLATION SETUP 13 2 1 SAFETY PRECAUTIONS 13 2 2 INSTALLATION SITE 13 2 2 1 MOVABLE METALLIC ITEMS 13 2 2 2 FLOOR VIBRATION 13 2 2 3 ELECTROMAGNETIC...

Page 7: ...7 SYSTEM PASSWORD 25 4 8 RECORD QUERY 25 4 9 SYSTEM SETTINGS 26 4 9 1 SLEEP MODE 27 4 9 2 TIME SETTINGS 27 4 9 3 LANGUAGE 28 4 9 4 RESET 28 4 10 SYSTEM INFO 29 4 11 COMMUNICATION 29 4 11 1 NETWORK SE...

Page 8: ...is a metal detection pole that offers a checkpoint specific solution to airports bus terminals conferences customs docks and railway stations FMD Pro 2 0 can detect concealed metal objects smartphone...

Page 9: ...FMD Pro 2 0 User Manual and Installation Guide Copyright 2022 ZKTECO CO LTD All rights reserved P a g e 8 1 3 Dimensions...

Page 10: ...m Throughput Rate 50 people minute Sensitivity Level 100 Alarm Zone 3 zones Touch Screen Size 3 5inches Alarm Volume 1 to 10 Levels Alarm Ring 6 Types selectable Input Voltage 15V Embedded Rechargeabl...

Page 11: ...ication s CE FCC 1 5 Performance and Technical Features Adjustable Sensitivity Each detection zone has 100 sensitivity levels 0 to 100 You can preset the metal size by excluding coins keys jewelry bel...

Page 12: ...Distance Since different objects have different lengths volumes masses densities etc the detection distance for each different object is also different Please refer to the actual detection location f...

Page 13: ...and Installation Guide Copyright 2022 ZKTECO CO LTD All rights reserved P a g e 12 1 7 Components 1 Indicator 2 Speaker 3 3 5 inch Touch Screen 4 Alarm Zone LED 5 Power Button 6 Foot Cup 7 Magnetic Se...

Page 14: ...e The following section describes the requirements of the installation environment 2 2 1 Movable Metallic Items The movable metallic objects must be kept away at 2 meters from the detector to avoid fa...

Page 15: ...ower Motor Power Transformer AC Power Lines Thyristor Control Circuit High Power Switching Power Supply Inverter Welder Engine Motor etc 2 2 4 Installation Steps Make sure that the device is installed...

Page 16: ...022 ZKTECO CO LTD All rights reserved P a g e 15 Install on the wall 1 Fix the back plates on the wall according to the pole position using wall mounting screws 2 Attach the pole to the back plates No...

Page 17: ...The FMD Pro 2 0 detector can detect a wide range of threat objects weapons composed of magnetic The three detection zones and accurate detection ensures that if the metal composition reaches or excee...

Page 18: ...All rights reserved P a g e 17 4 Operational Procedure Connect the power supply to the detector Press the power button and after 5 seconds of initialization you can perform the following operations Pr...

Page 19: ...the sensitivity of detection The larger the value the more sensitive the system would be i e if a larger value is set the probe zone is much easier and frequently triggered The valid value ranges fro...

Page 20: ...ta security Record Query When a person passes through the metal detection pole the corresponding details will be saved in the device This function allows the user to check the detection records System...

Page 21: ...zone to be adjusted adjust the sensitivity of the zone in the zone interface and click Confirm OK to save 4 3 Security Level Setting Here the metal detection level can be set to different security lev...

Page 22: ...tting The settings can be selected for security inspections at access points at airports customs docks prisons train stations and bus stations Click Application Area on the main menu Select the applic...

Page 23: ...FMD Pro 2 0 User Manual and Installation Guide Copyright 2022 ZKTECO CO LTD All rights reserved P a g e 22...

Page 24: ...s of alarms when the metal composition reaches or exceeds the preset value The default value is 2 Alarm Tone Select an alarm tone from the available options Relay Delay Set the alarm delay time the la...

Page 25: ...ghts reserved P a g e 24 Menu Descriptions Zone Test Check the detector by placing metal in the zone to check whether the detector is sensitive When a metal is placed in the zone the detector will ala...

Page 26: ...ed to improve the security of data Click System Password on the main menu Enter a password and re enter it Click OK If the two entered passwords are different the prompt Password not match will appear...

Page 27: ...All rights reserved P a g e 26 Select the time range you want to search records press OK the system will search and display the respective record 4 9 System Settings You may customize the screen slee...

Page 28: ...n the System Settings interface If you have activated the sleep mode when there is no operation the device will enter the standby mode Press any key or finger to resume the normal working mode You can...

Page 29: ...ights reserved P a g e 28 You can manually set date and time and click Confirm to save 4 9 3 Language Click Language on the System Settings interface to select the language of the device To select the...

Page 30: ...tings to factory settings does not clear the data Click OK to reset 4 10 System Info Click System Info on the main menu Here you can view the device name serial number MAC address firmware manufacture...

Page 31: ...e 30 4 11 1 Network Settings Click Ethernet on the COMM interface Menu Descriptions IP Address The default IP address is 192 168 1 201 It can be modified according to the network availability Subnet M...

Page 32: ...work availability TCP COMM Port The default TCP COMM Port value is 4370 It can be modified according to the network availability DHCP Dynamic Host Configuration Protocol dynamically allocates IP addre...

Page 33: ...thod is RS232 RS485 you need to input this device ID in the software communication interface 4 11 3 Wireless Network Click Wireless Network on the COMM interface Tap on the required Wi Fi name from th...

Page 34: ...pyright 2022 ZKTECO CO LTD All rights reserved P a g e 33 On this interface enter the WIFI network parameters The added network must exist Advanced Setting On the Wireless Network interface tap on Adv...

Page 35: ...cannot be set manually IP Address The IP address for the WIFI network the default is 0 0 0 0 It can be modified according to the network availability Subnet Mask The default Subnet Mask of the WIFI ne...

Page 36: ...ddress Once this mode is turned ON the domain name mode http will be used such as http www XYZ com while XYZ denotes the domain name Disable Domain Name Server Address The IP address of the ADMS serve...

Page 37: ...ight 2022 ZKTECO CO LTD All rights reserved P a g e 36 Packing List The package consists of the following items S No Component Quantity 1 Pole 1 2 Base 1 3 Plates 2 4 Screw 8 5 Plastic Plug 8 6 User M...

Page 38: ...www zkteco eu Copyright 2022 ZKTECO CO LTD All rights reserved...

Reviews: