C3-200 Installation Guide
4.
LED Indicators, Wires, Auxiliary Input and Output
Notes
:
1.
Cautions
Vision
: 1.0.1
Date
:
Oct.
2010
1) Meaning of LED indicators
:
LINK
indicator (green): always (green) indicates TCP/IP
communication is proper;
ACT
indicator (yellow): flashing indicates data is transmitting
through TCP/IP communication.
TX
indicator (yellow): flashing indicates it is sending data through
RS485 communication.
2)
Recommended use of wires
:
A Use 2-conducotor power cord
B Use 6-conductor wire between Wiegand reader and control panel
(RVVP 6x0.5mm) (choose the appropriate cord for the interface
you connect, such as 6, 8, 10 cord)
C Use 4-conductor lock power cord (RVV 4x0.75mm)
Please note the following cautions. Mis-operation may lead to personal injury or equipment failure:
1)
Do not energize the system before installation is complete; never carry out installation activities when the system is energized.
2)
All peripheral devices must be grounded.
3)
It is preferred that all wires run through PVC or galvanized conduit.
4)
It is strongly recommended that the length of exposed part of any connection cable not be longer than 4 mm. Professional
clamping tools may be used to avoid unintentional contact of exposed wires to avoid short-circuit or communication failure.
RX
indicator (green): flashing indicates it is receiving data through
RS485 communication.
Auxiliary output
indicator (green): always (green) indicates it is in use.
Lock
indicator (green): always (green) indicates lock is open.
POWER
indicator (red): always (red) indicates control panel power is
on.
RUN
indicator (green): flashing indicates the system works normally.
CARD
indicator (yellow): flashing indicates card is punched on reader.
D Use 2-conductor switch power cord
(
RVV 2x0.5mm
)
3)
The auxiliary input may be connected to infrared body detectors,
alarms, switches, etc.
4)
The auxiliary output may be connected to door bells, alarms, etc.
5)
It is recommended that card readers and buttons be installed at a height of 1.4m-1.5m above ground.
6)
It is recommended to use the accompanying power supply for the control panel and external power supply for each lock.
Description of normal working state:
Connect the system to the power supply. If the system works properly the POWER indicator (red) is lit constantly and the RUN
indicator (green) flashes.
Ethernet interface
LINK
ACT
SD card
IN
GND
IN
GND
+12
V
GND
D
Auxiliary input1
D
Auxiliary input2
Extended
2.
Components
Dip switch
485-
485+
RS
485
output
D
Backup battery
Power supply
Control panel
Advanced Access Control
TX
IN
GND
1# Door
Button
Heat
dissipation
hole
Key hole
Thread hole
PC RS485 interface
D
Auxiliary output 1
D
485+
485-
GND
TX
RX
NO
COM
NC
RX
BEEP
GLED
WD
1
WD
0
GND
+12
V
BEEP
GLED
B
1#Door
Wiegand reader
B
Appearance of case
3.
Get through the thread hole
Thread hole
Auxiliary output 2
{
C
Door
1
C
Door
2
Power to lock
A
Power to Control panel
NO
COM
NC
SEN
GND
NO
COM
NC
SEN
GND
NO
COM
NC
V
-
+12
V
POWER
WD
1
WD
0
GND
+12
V
IN
GND
BEEP
GLED
WD
1
WD
0
GND
+12
V
BEEP
WD
1
WD
0
GND
1#Door
Wiegand reader
D
2# Door
Button
B
2#Door
Wiegand reader
2#Door
Wiegand
reader
GND
RUN CARD
+12
V
1
2
Get through the thread hole
Fixed case