Installation Guide for SCR100 Device

I

Install device

II

Access

 

control system overview

 

RS232/RS485

 Converter

Card

reader

Release

button

Alarm

Lock

Door

sensor

Warning: Don’t connect wires with power on!

III

Connect

 

to

 

door

 

lock

1

device and lock share power supply

NC lock

NO lock

Notice:If lock’s working power is 

 

DC12V,

 and working current is least 1000mA less
 than that of access 

 

control device  power

 supply, wiring 

 

with sharing power supply

 can be 

 

adopted. 

Notice: Wiring with lock power 

 

supplied 

independently 

 

is recommended for the 

  following 

 

states: 

1) Lock’s working power is DC 12V,
 

power’s current is 

 

device 

not 1A more

 than that of lock.
2)Lock’s standard voltage is not 

 

DC12V.

3)The distance between lock and 

 

device

 is long.

NO lock

NC lock

Connection with other device

Alarm

Alarm
power

Release

button

Door sensor

2

device

 

and

 

lock

 

don’t

 

share

 

power

 

supply

DC Power

DC Power

DC Power

1)Post the mounting template on
the wall. Drill holes according to
the marks on the template.(Holes  
for screw and wiring)

3) Take away the screw on 
the bottom of device

2)Take off the water-proof cushion

5)Fix the cushion and plate on 
the wall 

4) Release the mounting plate

6) Fix the device with the plate
after all wiring completed

Access 

 

control device can be  connected with external out-go     

switch, which provides convenience to open door from the inside.

 When a registered person verified, the access  

 

control  device

will export  signal to open the door.

 Door sensor will detect on-off state to sense 

 

whether the door

is  opened  by accident or  the door is not closed well, alarm will

 

If access control device is torn down illegally, 

 

or door  sensor

is abnormal,  or menace alarm gives off,  the device will export

 Connect a Weigand reader to work as a controller.

Access control software to manage multi devices 

 

via RS485

Access control system

alarm signal.

 or TCP/IP.

The device could connect to NC or NO locks, the connection terminal is not same, please according to the following
 diagram to make connection.        

 1)The rating output of the alarm no more 

 

than DC12V.

 

The device’s working voltage is DC12V, with 
working current 500mA,standby current 50mA . 
Make sure the connection as the diagram(

Don’t

connect the poles in reverse.

).

.

Power connection 

 be given off under

 

abnormal condition.

Notice:

2)The device has no bell button

,

so BELL

and BELL-

 

  

terminals don’t work temporarily.

+

-

FR 107

+

-

FR 107

+

-

FR 107

+

-

FR 107