background image

 

22/01/2014 – Revision 01 – DE/EN 

 
 
 
 
 

CZ 

Návod k použití 

Čerpadlo na čistou a znečištěnou 

vodu 

EN 

Operation Manual 

Clean & Dirt Water Pumps 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ZI-CWP400 / ZI-DWP900 / ZI-DWP1100N 

 

EAN: 9120039230016 / 9120039230023 / 9120039230030 

 
 
 
 

CZ 

Před použitím si přečtěte a dodr-

žujte návod! 

EN 

Read the operation manual care-

fully before first use! 

 

Z

IP

P

E

R

 M

a

s

c

h

in

e

n

 G

m

b

H

 

G

e

w

e

rb

e

p

a

rk

 8

 

A

-

4

7

0

7

 S

c

h

s

s

lb

e

rg

 

T

e

l.

+

4

3

 7

2

4

8

 6

1

1

1

6

-

7

0

0

 

F

a

x

+

4

3

 7

2

4

8

 6

1

1

1

6

-

7

2

0

 

E

-

M

a

il

in

fo

@

z

ip

p

e

r

-

m

a

s

c

h

in

e

n

.a

W

e

b

w

w

w

.z

ip

p

e

r

-

m

a

s

c

h

in

e

n

.a

Summary of Contents for ZI-DWP900

Page 1: ...6 9120039230023 9120039230030 CZ P ed pou it m si p e t te a dodr ujte n vod EN Read the operation manual care fully before first use Z I P P E R M a s c h i n e n G m b H G ew e r b e p a rk 8 A 4 70...

Page 2: ...2...

Page 3: ...lations on the purchase of your new ZIPPER pump This manual contains impor tant information and advice for the correct and safe use and maintenance of the pump models ZI CWP400 ZI DWP900 ZI DWP1100N T...

Page 4: ...ezpe nost P ed pou it m erpadla si nechte kvalifikovan m elektromechanikem zkontrolovat n sleduj c za zen zemn n nulov vodi innost proudov ho chr ni e elektrick p ipojen mus b t chr n no proti vlhkost...

Page 5: ...ch kde je nutn prov d t erp n vody nap v dom cnosti na zahrad sanit rn oblasti apod UVEDEN DO PROVOZU Po p e ten tohoto n vodu m ete erpadlo uv st do provozu Dbejte pros m na n sleduj c body zkontrolu...

Page 6: ...i provozu k b hu bez kapaliny P ed uveden m erpadla do provozu zkontrolujte n sleduj c body plov k mus b t nastaven tak aby polohy zapnuto ON a vypnuto OFF byly lehce dosa iteln Ke kontrole a nastaven...

Page 7: ...it dol um st te erpadlo spr v n na spodn plochu Nedostate n pr tok ucpan vstupn filtr sn en v kon d ky zne i t n kapalin vy ist te vstupn filtr vy ist te erpadlo a na hra te opot eben d ly erpadlo se...

Page 8: ...WP900 ZI DWP1100N Nap t kmito et 230V 50Hz 230V 50Hz 230V 50Hz V kon 400W 900W 1100W Max v kon erpadla 7 3m3 h 14m3 h 15m3 h Max v ka erp n 7 5m 9m 10m Max hloubka s n 7m 8m 8m Max velokost ne istoty...

Page 9: ...g items checked by an expert Ground connection Zero conductor Fault current breaker switch must correspond the safety regulations of the power plants and they must work faultlessly The electrical conn...

Page 10: ...ian AREAS OF USE This pump is used primarily as cellar pump when installed in a shaft this pump provides protec tion from flooding They are also used wherever water has to be moved from one place to a...

Page 11: ...into operation please check the following The float switch must be installed so that the level of the ON operating point and the level of the OFF operating point can be reached easily and with little...

Page 12: ...ficient flow Inlet sieve is clogged Reduced pumping capaci ty by dirty and abrasive water Clean inlet sieve Clean pump and replace worn out parts Pump switches of after shout operation period Thermal...

Page 13: ...400 ZI DWP900 ZI DWP1100N Voltage Frequency 230V 50Hz 230V 50Hz 230V 50Hz Rated Power 400W 900W 1100W Max Pump Rate 7 3m3 h 14m3 h 15m3 h Max Height 7 5m 9m 10m Max Depth 7m 8m 8m Max Grain Size 5mm 3...

Page 14: ...14 CZ SCH MA KONSTRUKCE EN EXPLOSION VIEW...

Page 15: ...EN 61000 3 3 2008 T mto prohla ujeme e v e uveden stroj spl uje po adavky uveden ch sm rnic EU Toto prohl en ztr c svou platnost pokud na stroji byly provedeny zm ny kter n mi neby ly odsouhlaseny Her...