OPERATION
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
21
ZI-COM50-10
15.2
Operation
Switch on:
Push the ON-OFF-switch “
1
”
Switch off:
Push the ON-OFF-switch “
0
”
Setting output pressure:
The output pressure can be set with the pressure regulator
Output pressure:
The output pressure is shown on the manometer output pressure
Pressure switch adjustin:
The pressure switch is set at the factory.
Starting pressure ca. 8 bar
Stoping pressure ca. 10 bar
Before use, check whether the compressor switches off when the switch-off pressure is reached.
Afterwards, check the pressure of the compressed air by means of a compressed air tool to ensure that
the compressor starts up again when the pressure is reduced
Output:
To connect a device place the union joint into the coupling. The sleeve will go to starting position
automatically. To disconnect pull the sleeve backwards and remove the hose.