TROUBLE SHOOTING
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
25
ZI-STE2800IV
14
TROUBLE SHOOTING
Trouble
Possible cause
Solution
Engine does not start
Incorrect starting sequence
Observe the correct starting
sequence
Dirty air cleaner
Clean/replace air cleaner
No fuel supply
Refuel
Fault in the fuel line
Check the fuel line for kinks
or damages
Engine flooded.
Screw off, clean and dry the
spark plug. Then pull the
cranking rope several times
and reinstall the spark plug
Spark plug connector not placed on.
Place on the spark plug
connector
No ignition spark
Clean/replace spark plug
Check ignition cable
Fuel cock closed
Open fuel cock
Engine oil to few
Check engine oil
Engine starts and is stalled
immediately
Incorrect idle adjustment
Contact customer service
Machine works with
interruptions
Carburetor incorrectly adjusted
Contact customer service
Spark plug fouled
Clean/replace spark plug
Check spark plug connector
Low oil light glows
Check oil level
Fill engine oil
Low oil light glows
To less or no oil
Fill engine oil
Overload indicator light glows
Low voltage protection activated
Engine speed to low
Overload indicator light glows
High temperature protection
activated
Cool down the engine
Overload indicator light glows
Overload protection activated
To big loads
Overload indicator light glows
Short circuit protection activated
Check loads
N O T I C E
Should you in necessary repairs not able to properly to perform or you have
not the prescribed training for it always attract a workshop to fix the
problem.