MAINTENANCE
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
27
ZI-RPE125
27
Stopping the Machine
16.4.1
Emergency Stop
In case of danger and/or in an emergency situation, you can quickly switch off the machine
with the speed governor by pushing it completely into the STOP position.
16.4.2
Normal switch-off
1.
Set the upper throttle lever to "minimum" and let the engine run idle for approx. 3
minutes at low engine speed.
2.
Then set the engine ON/OFF switch (ignition switch) to the OFF position.
3.
Close the fuel switch.
4.
Wait until the engine has cooled down before storing the machine.
Moving machine forward / backward
Use the lever (S) to determine the direction of travel. Depending
on the position of the lever, the machine moves forwards or
backwards.
The machine should be steered at the bracket (B).
Note for reverse driving:
Operate the machine from the side + pay special attention to the
working environment (free of obstacles, danger of tripping) to
avoid danger of crushing.
17
MAINTENANCE
W A R N I N G
Hot surfaces and rotating machine parts while the engine is running can cause
serious injury or even death. Always stop the machine before carrying out any
conversion, adjustment, cleaning or maintenance work and secure it against
unintentional restarting.
Maintenance and Servicing PLan
17.1.1
Table of Measures
What to do?
Frequency
Check fuel level
before each start-up
Check engine oil level
before each start-up
Control of the operating elements
before each start-up
Check for damaged parts
before each start-up
Checking for loose or lost screws
before each start-up
Change engine oil
first after 20 h, then every 100 h
Check V-belt
every 50 h; replacement after 300 h
Change exciter oil
every 200 h
Air filter cleaning
every 50 h, replacement after 300 h or 1
year
Spark plug test
every 100 h; replacement after 300 h or 1
year
The specified intervals refer to working under "normal" operating conditions. Depending on the
load, a change/exchange may also be necessary at an earlier point in time.