ASSEMBLY
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
31
ZI-TKS315_400V
14.2
Power supply
A T T E N T I O N
When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore
: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power socket!
2.
The mains supply must be secured with 16A:
3.
If the connector plug doesn’t fit or if it is defect, only qualified electricians may modify or re-new
it!
4.
The grounding wire should be held in green-yellow.
5.
Check, whether the feeding voltage and the Hz comply to the required values of the machine. A
deviation of feeding voltage of ±5% is allowed (e.g.: a machine with working voltage of 380V can
work within a voltage bandwidth of 370 till 400V.
6.
After connecting, check the right running direction!
7.
Make sure that a possible extension cord is in good condition and suitable for the transmission of
power. An undersized cord reduces the transmission of power and heats up.
8.
A damaged cable must be replaced immediately
N O T I C E
Operation is only allowed with safety switch against stray current
(RCD max. stray current of 30mA)
N O T I C E
Use only permitted extension cable with cross-section the one in
the following table declared.
Plug 400V:
5-wire:
with
N-conductor
4-wire:
without
N-conductor