TRADEMARKS
Zipato and the Zipato logo are registered Trademarks. All
other product names mentioned herein may be trademarks or
registered trademarks of their respective companies.
NOTICE
Although Zipato has attempted to ensure the accuracy of the
content of this manual, it is possible that this document may
contain technical inaccuracies, typographical, or other errors.
Zipato assumes no liability for any error in this publication, and for
damages, whether direct, indirect, incidental, and consequential
or otherwise, that may result from such error, including, but not
limited to loss of data or profits. Zipato provides this publication
“as is” without warranty of any kind, either express or implied,
including, but not limited to implied warranties of merchantability
or fitness for a particular purpose. The published information in
the manual is subject to change without notice. Zipato reserves
the right to make changes in the product design, layout, and driver
revisions without notification to its users. This version of the
Installation guide supersedes all previous versions.
ELECTROMAGNETIC COMPATIBILITY
In proper state and when operated properly, the product complies
with all the requirements in respect of interference radiation
according to EN 301 489-17, EN 301 489-1 and EN 300 328. The
connections conducting HF signals must neither be manipulated
nor damaged.
TAKE CARE OF YOUR SAFETY
Display extreme caution when using ladders or steps, please
follow manufacturer’s instructions. Be careful when using hand
and power tools and follow the manufacturer’s guidelines when
using them. Take care that the correct tools are used. Wear
goggles or protective clothing where required.
INTRODUCTION
Thanks for choosing the Zipato’s wireless PIR motion sensor of the
home security device. This sensor is a Z-Wave TM enabled device
(interoperable, two-way RF mesh networking technology) and is
fully compatible with any Z-Wave TM enabled network. Every mains
powered Z-Wave TM enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which
helps eliminate “RF dead-spots”.
Z-Wave TM enabled device displaying the Z-Wave TM logo can also
be used with it regardless of the manufacturer, and ours can also
be used in other manufacturer’s Z-Wave TM enabled networks.
This sensor monitors movement, and send Z-Wave TM signal when
movement is detected inside the building.
3 |
Close the cover back to sensor.
4 |
FOR “INCLUSION” IN (ADDING TO):
Put the Z-Wave TM Interface
Controller into “inclusion” mode, and following its instruction to add
the Vs- to your controller. To get in the “inclusion” mode, the
distance between sensor and controller is suggested to be in one
meter. Press the program switch of Vs- once. The LED on
the Vs- should stop flashing, if not, please try again.
FOR “EXCLUSION” FROM (REMOVING FROM) A NETWORK:
Put the
Z-Wave TM Interface Controller into “exclusion” mode, and following
its instruction to delete the Vs- to your controller. Press the
program switch of Vs- once to be excluded. The LED on the
Vs- should start to flash.
FOR “ASSOCIATION”:
removing the cover of the Vs- to get
into “Awake” mode, then put the Z-Wave TM Interface Controller
into “association”, and following its instruction to associate the Vs-
with other device. Close the cover back after “association”
done, afterward the Vs- will get into “Sleep” mode for power
saving. Support one association group (5 nodes).
NOTE: ”AWAKE” MODE:
it is to leave the “Sleep” mode by removing
the cover of Vs-, to allow the Z-Wave TM Interface Controller
to do “Association”.
5 |
Using adhesive tape to mount Vs- at 2 meters above
surface. To enhance proper operation, place Vs- on the
angle which can detect the room widely. The solid area means the
detector’s coverage range.
OPERATION
1 |
Walk in front of Vs-, sensor will send the status of “ON”
(Basic Set,Value:0xFF) to any associated nodes, and the LED will
flash once.
2 |
If no movement detected in three minutes after sent status
of “ON”, the sensor will send the status of “OFF” (Basic Set,
Value:0x00) to any associated nodes
3 |
Normal operation, the LED will not light.
4 |
The Vs- sensor equipped with tamper switch. If the
cover of sensor is removed, the PIR sensor will send an alarm
report (type:01, level:11) to the Z-Wave™ Interface Controller, and
the LED will go solid. Before replacing the cover, the sensor is uder
“Awake” mode.
TECHNICAL SUPPORT
Having trouble installing your new product?
Zipato’s website contains the latest user documentation and
software updates for Zipato products and services.
www.zipato.com
CONTACT SUPPORT
E-MAIL: [email protected]
(Mon-Fri) 9.00am-05.00pm (CET)
SPECIFICATION
TECHNICAL SPECS
PROTOCOL
Z-Wave™ (ZM3102N)
OPERATING RANGE
Up to 100 feet line of sight
OPERATING TEMPERATURE
-15°C - 40°C (5°F - 104°F)
BATTERY
Panasonic CR123A * 1PC
PACKAGE CONTENT
1PC
ZP 3012 sensor
1PC
Adhesive tape for sensor
1PC
CR123A Lithium Battery
1PC
Installation & Operation Manual
INSTALLATION
Notice: If you are installing the entire Z-Wave TM system for the first
time, please refer to the installation guide of Z-Wave TM Interface
Controller before installing Vs-.
1 |
Release cover tab to open the cover.
2 |
Insert a CR123A battery into the battery compartment, and LED
will start to flash slowly, which means the sensor has not yet been
“inclusion”.
MULTI SENSOR
DUAL
QUICK INSTALLATION GUIDE
v1.3
PRODUCT DESCRIPTION AND
SPECIFICATION
Program
Switch
Adhesive
Tape
Battery
Sensor
Tamper
switch
Lens
Tab to
release cover
LED status
indicator
KEEP THE
SURFACE
OF SENSOR
AND LENS
CLEAN
WIPE WITH
CLEAN
AND SOFT
CLOTH
SENSOR
1M
0
1
2
3
4
5
6
7
8
9
10
C
B
A
LENGTH
10M
SENSOR
C
B
A 0°
10°
20°
30°
40°
50°
60°
10°
20°
30°
40°
50°
60°
0 1 2 3 4 5 6 7 8 9 10
M
M
make your home smart
www.zipato.com
make your home smart
www.zipato.com
01