Zip VP103 Installation, Maintenance & User Instructions Download Page 1

ZIP

Varipoint II

Models VP103, VP153

VP103UB, VP153UB

unvented water heaters

Issued November 2010

Installation, Maintenance

and User Instructions

Please read these instructions carefully

before

commencing installation

of the Varipoint unvented water heater.

Please leave these instructions with the end user after installation.

Zip Heaters (UK) Ltd
14 Bertie Ward Way
Dereham Norfolk NR19 1TE
Telephone 0845 602 4533
Facsimile 01362 692448
www.zipheaters.co.uk
[email protected]

The terms ‘Zip’ and ‘Varipoint’ are registered trademarks.

Zip products described in the brochure are manufuctured

under one or more of the following patents: AU675601,

AU637412, AU635979, GBO422305, GB2065848,

US4354049, US5103859, US5099825. Other patents are

in force and patent applications are pending.

Varipoint II cover qxd:Varipoint cover qxd  26/10/10  10:22  Page 1

Summary of Contents for VP103

Page 1: ...ation Zip Heaters UK Ltd 14 Bertie Ward Way Dereham Norfolk NR19 1TE Telephone 0845 602 4533 Facsimile 01362 692448 www zipheaters co uk info zipheaters co uk The terms Zip and Varipoint are registere...

Page 2: ...abuse condition of the water frost or failure to follow installation instructions or service requirements The only charges payable by the customer are the cost of removal re installation and cartage s...

Page 3: ...sitioning 9 Plumbing 9 Electrical 10 Commissioning 10 11 Operation Precautions 11 12 Maintenance Schedule 13 Fault Finding 13 De Install 13 Spare Parts 14 Zip Varipoint II Installation Maintenance and...

Page 4: ...atures Expansion relief valve supplied Set to 6 bar Manually resettable over temperature safety cutout Facility for T P valve supplied Set to 90 C 7 bar Water heater protected against frost when elect...

Page 5: ...istant plastic and heat losses are minimised by the CFC free polyurethane foam insulation I The inner vessel is heavy gauge copper and pressure tested to 16 bar I An alloy sheathed heating element pro...

Page 6: ...Centres Weight Water litres mm mm kg Connections A B C D E F Empty Full VP103 10 452 300 285 60 420 142 6 5 16 5 1 2 BSP VP103UB 10 452 300 285 60 335 142 6 5 16 5 1 2 BSP VP153 15 452 300 285 60 420...

Page 7: ...Where the expanded water cannot be accommodated in the pipe work and the static water supply pressure is under 4 bar fit accessory pack AQ2 Expansion vessel and check valve Where static water pressure...

Page 8: ...bar but expanded water cannot be accommodated in the pipework Using pack AQ2 expansion vessel and check valve Diagram 3 Inlet pressure is greater than 4 bar Using pack AQ2 and AQ3 expansion vessel che...

Page 9: ...in a roof space cupboard or any concealed location For guidance please ring Zip Heaters on 0845 602 4533 5 Position the Zip Varipoint to allow for future maintenance 6 Do not install in a location whe...

Page 10: ...Release the one screw revealed by the knob c Remove the cover by sliding forwards d Pass the new cable through the entry point of the cover e Remake the connections f Ensure the cable is securely cla...

Page 11: ...tings This setting protects the appliance against frost damage but this protection does not extend to connecting pipework or fittings 45 C Economy setting 60 C Standard setting 75 C Setting for very h...

Page 12: ...on has has checked it is safe to do so 7 The heater should be visually inspected regularly This is particularly important if the heater is located in a cupboard roof space or any other concealed locat...

Page 13: ...hould be replaced after 5 years Fault Finding Fault Possible causes Water not heating 1 Electricity supply fault 2 Over temperature cut out tripped 3 Faulty thermostat 4 Faulty element Discharge from...

Page 14: ...P0303 Thermostat 3 VP0304 Resettable Cut Out 4 VP0317 Element Gasket 5 VP0322 Wall Fixing Bracket Spare Parts 5 2 3 1 4 5 2 3 1 4 Zip Varipoint II Underbasin Item Part No Description 1 VP0302 Element...