UNItivity 5000
Hub and Module LEDs
User Manual
Copyright © 2022 Zinwave. All rights reserved.
3-12
3.3.1 Power LED
—Right
LED
Color
Description
Dull Red
Initial power-up. Power present on Hub allowing Module detection to
proceed; or
Module NOT Enabled through System Setup; or
Module not inserted in valid Hub slot.
Green
Module in normal operation. Ready for use (Power to module).
Off
No power to module.
3.3.2 Communications
—Middle
Once plugged in, the Optical or Transport Module attempts to establish communication with the far end.
Service Modules do not communicate with Remote Units or other Hubs; therefore, the Communications
LED is deactivated for Service Modules.
3.3.3 Status
—Left
LED
Color
Service Module
Optical / Transport Module
Off
Normal condition
Module is not powered, or optical calibration and auto-
setup of downstream units not yet completed.
Green
Not Used
Optical / Transport Module and all downstream system
elements operating normally.
Flashing
Green
Not Used
Optical link calibration and auto-setup of downstream units
in progress; and/or
One or more downstream Remote Units have their radio
transceivers disabled.
Flashing
Orange
Flashing Orange
RF Path Calibration or RF System Check in progress
Red
Not Used
Optical calibration and auto-setup Error
– For Possible
causes refer to “System Status” page on GUI
LED
Color
Optical / Transport Module Description
Solid Red
No successful communication with any downstream system elements after initial
attempts.
Green
Module in normal operation. Communication established with at least one
downstream system element.
Off
Module is not powered or has not yet completed initial attempts to communicate
with downstream system elements.
Summary of Contents for UNITIVITY 5000