14 Declaration of Incorporation

In terms of the EU Machinery Directive 2006/42/EC (Annex II 1 B)

Name and address of the manufacturer:
Zimmer GmbH

Im Salmenkopf
77866 Rheinau, Germany
+49 7844 9138 0

[email protected]
www.zimmer-group.com


We hereby declare that the incomplete machine described below

Product designation:

MATCH needle gripper

Type designation:

LWR50L-27 series

conform to the requirements of the Machinery Directive, 2006/42/EC, Article 2g, Annex VII.b – Annex II.b, in its design and 

the version we put on the market.

Basic health and safety requirements:
No. 1.1.2, No. 1.1.3, No. .1.5, No. 1.3.2, No. 1.3.4, No. 1.3.7, No. 1.5.3, No. 1.5.4, No. 1.5.8, No. 1.6.4, No. 1.7.1, No. 1.7.4
A full list of applied standards can be obtained from the manufacturer.

We also declare that the specific technical documents were produced in accordance with Annex VII Part B of this Directive. 

We undertake to provide the market supervisory bodies with electronic versions of special documents for the incomplete 

machine through our documentation department, should they have reason to request them.

The incomplete machine may only be commissioned if it has been ascertained, if applicable, that the machine or 

system in which the incomplete machine is to be installed satisfies the requirements of Directive 2006/42/EC on 

Machinery and an EC Declaration of Conformity has been drawn up in accordance with Annex II 1 A.

Kurt Ross

Rheinau, Germany, 2022-05-17

Authorized representative for the 

compilation of relevant technical 

documents

(Place and date of issuance)

Martin Zimmer

(Legally binding signature)

Managing Partner

INSTALLATION AND OPERATING INSTRUCTIONS: 

LWR50L-27

DDOC01645 / -

EN / 2022-08-08

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Summary of Contents for MATCH LWR50L-27 Series

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS MATCH needle gripper LWR50L 27 series DDOC01645 THE KNOW HOW FACTORY www zimmer group com...

Page 2: ......

Page 3: ...l 11 6 4 Self locking mechanism 11 7 Technical data 11 8 Accessories scope of delivery 11 9 Transportation storage preservation 11 10 Installation 12 10 1 Installing the product 12 10 1 1 Installing t...

Page 4: ...ing these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can...

Page 5: ...s or additions to the intended use of the product as well as modifications to the product such as those in the following examples require the written permission of the manufacturer Use of the product...

Page 6: ...is designed exclusively for pneumatic operation The product is intended for industrial use The product is to be used as intended in enclosed rooms for temporary gripping handling and holding The produ...

Page 7: ...ces MATCH is compatible with all common lightweight robots The system can be mounted on the robot flange and set up with a few manual adjustments The product is a safe quick change system MATCH grippe...

Page 8: ...er the jaws are pushed outward and the needles extend a defined length The workpieces are gripped by piercing The return movement is done by a spring and by de aerating the pneumatic cylinder To relia...

Page 9: ...spond if the lockings are extended and make contact in the MATCH robot module When the MATCH robot module and MATCH gripper are joined the internal spring pin contacts for signal transmission are cont...

Page 10: ...ings of the MATCH storage station Turn in the sensors until they emit a signal Fasten the sensors at this position Coat the sensors with sealing lacquer 6 1 3 Adjust the sensors in the storage positio...

Page 11: ...ories are specifically tailored to the individual products For optional accessories and those included in the scope of delivery refer to our website 9 Transportation storage preservation Transport and...

Page 12: ...cure the power supply against being switched on unintentionally Check the machine for any residual energy that may be present NOTICE Installation may only be carried out by qualified personnel in acco...

Page 13: ...manually Automatic exchange The MATCH robot module is moved to the MATCH gripper in the MATCH storage station and locked by means of the MATCH storage station see Sensors section Rotation prevention T...

Page 14: ...n applications that require high EMC shielding The movement of the needles creates low voltages as a result of static charging These charges cannot be dissipated if the product is mounted on an insula...

Page 15: ...Setting the sensors The sensors query whether the needles are extended or retracted 9 bm bn bl Remove the mounting screws Remove the adapter plate Turn the adjustment screw using an Allen key 9 Adjus...

Page 16: ...with the power specifications Ambient temperature is too high Even though the product is maintenance free as mentioned above perform a regular visual inspection to check for any corrosion damage or co...

Page 17: ...ific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents for the...

Reviews: